INSTALLATION
FUZION™ Control Panel Installation
NOTE: The Fuzion™ control panel is delivered loose and
must be installed during the tub install.
For Fuzion™ drop-in and undermount installations, install
the control panel as shown below.
The control panel cutout opening in the assembled wood
frame and tub and in the assembled counter and tub must be
clear and free of adhesive.
Control panel and wire to be free of defects. Insert wire
into panel connector.
Apply adhesive sparingly around base of control panel.
Thread wire through cutout and to control box. Orientate
control panel so that the Jacuzzi logo is read from the inside
of the tub. Lower control panel in cutout and press rmly to
embed adhesive.
Connect wire to control box.
Adhesive
Apply sparingly to
avoid squeeze out
Connect Blower
wire here
(Grey wire)
Connect Control Box
wire here
(Black wire)
Inside of tub
Inside of tub
ELECTRICAL CONNECTION
115 VAC
DUPLEX
RECEPT GFCI
(NOT PROVIDED)
115 VAC
3 PRONG
PLUG FROM
JUNCTION BOX
FLOOR
4" MIN.
OR IN
ACCORDANCE
WITH LOCAL
BUILDING OR
ELECTRICAL
CODES
HEATER BLANK
PUMP/MOTOR AND BLOWER FOR MITO™ 6
The Mito™ 6 unit comes with a blower, a pump/motor, and a heater blank. The Inline Heater must be purchased separately.
Follow the installation instructions provided with the Inline Heater if an Inline Heater has been purchased separately and is to be
installed at this time. The blower and pump motor are connected to a 120 VAC junction box.
Install a 120 VAC, 20 AMP RATED GFCI single outlet to the studwall underneath the bathtub, at least 4 inches (10,2 cm)
above the oor. The single outlet is not provided. A supplied power cord from the junction box with a 120 VAC plug connects to
the customer supplied GFCI dedicated circuit.
At initial start-up and before each use thereafter with power ON, push the GFCI test button. The reset button should pop
out. Push this button in to reset. If the interrupter fails to operate in this manner, there is a ground current owing or a device
malfunction, indicating the possibility of electrical shock. Turn OFF power and do not use the bath until the source of the
problem has been identi ed and corrected.
JUNCTION
BOX
PLUG INTO
120V 20AMP GFCI RECEPTACLE
FEMALE PLUG
120VAC, 7AMP
(FOR CONTROL BOX &
PUMP/MOTOR)
FEMALE PLUG
120VAC, 12AMP
(FOR BLOWER)
FUSE
(DO NOT REMOVE)
FUSE
(DO NOT REMOVE)
JUNCTION BOX CONNECTIONS
DANGER: RISK OF ELECTRIC SHOCK. Before servicing
these connections disconnect all power supply to 120
VAC service.
Electrical Connections (continued)