EasyManua.ls Logo

Jadever JCL-30K - User Manual

Jadever JCL-30K
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(II)
JCL 0
Content
1. Introduction..1
2. Precaution....................................1
3. Before Using the Product
3-1 Unpacking and Checking....1
3-2 Installing Components.....1
3-3 Leveling the Scale........1
4. Product Introduction
4-1 Specifications & General Features 2
4-2 Front Panel 3
4-2-1 Display . ......3
4-2-2 Keyboard.........4
4-3 Power Supply.........5
5. Setting Mode
5-1 Function Setting....5
5-2 Parameters.6
6. Single and Multi-point Calibration....8
7. Operation
7-1 Weighing9
7-2 Tare & Preset Tare.9
7-3 Checking function
7-3-1 Upper & Lower Weight Limit Checking ..10
7-3-2 Upper & Lower Quantity Limit Checking ....11
7-4 Basic Counting
7-4-1 Entering a Known Unit Weight and Unit weight Memory.12
7-4-2 Sample Counting and ACAL.12
7-5 Accumulation, Accumulation Display and Accumulation Clear...13
7-6 Initialization of the Scale to Printer (Optional)....14
7-7.The Control from PC to Scale (Optional)15
8. Serial Interface
8-1 RS-232 Connector.15
9. Troubleshooting and Error Message....16

Other manuals for Jadever JCL-30K

Questions and Answers

  • E
    Elizabeth MoraAug 20, 2025
    Why are my Jadever JCL-30K Scales showing wrong calibration weights?
    • B
      Brian WallaceAug 20, 2025
      If you encounter issues with calibration on your Jadever Scales, ensure you are using the correct test weights. The calibration value should also be below the full load capacity of the scale.
  • P
    Paul HarrisAug 22, 2025
    What to do if Jadever JCL-30K show overload condition?
    • T
      Tim NorrisAug 22, 2025
      If your Jadever Scales display shows an overload condition, remove the item that is causing the overload.
  • R
    Robert HooverAug 25, 2025
    What to do if accumulated weighments exceed display range on Jadever JCL-30K?
    • M
      Michael PetersonAug 25, 2025
      If the accumulated number of weighments on your Jadever Scales exceeds the display range, delete the exceeding weights to resolve the issue.
  • D
    dcookAug 26, 2025
    Why initial zero point exceeds 30% of full load on Jadever Scales?
    • A
      Amy AndrewsAug 26, 2025
      If the initial zero point exceeds 30% of the full load on your Jadever Scales: 1. Remove any obstructions under the pan. 2. If the issue persists, it may be necessary to replace the load cell or contact the maintenance department.
  • A
    Alexander HicksAug 28, 2025
    What causes Jadever JCL-30K to exceed tare or pre-tare range?
    • K
      katherinethompsonAug 28, 2025
      If your Jadever Scales exceed the tare or pre-tare range, ensure that the tare value is within the range of 0 to the full load.
  • P
    petersonreneeAug 29, 2025
    Why do Jadever Scales exceed the zero range?
    • R
      Roy HaleAug 29, 2025
      If your Jadever Scales exceed the zero range, ensure that the item on the pan is within 2% of the full load.
  • M
    martinezabigailAug 31, 2025
    Why won't my Jadever JCL-30K Scales power on?
    • J
      jonathansmithAug 31, 2025
      If your Jadever Scales fail to power on, several issues could be the cause. It might be due to a defective lead-acid battery. To check, remove the battery and try powering on the scale using the charging transformer. If it powers on, the battery is likely the problem. Alternatively, the charging transformer itself may be faulty; try using a known working transformer. Other potential causes include a fault in the CPU or crystal oscillating circuit (11.0592M), the LCD or related LCD circuit, or a power circuit fault. You should also check the ON/OFF switch for malfunction and replace it if necessary.
  • J
    javier77Sep 2, 2025
    Why are my Jadever JCL-30K Scales not charging properly?
    • A
      Anthony ElliottSep 2, 2025
      If your Jadever Scales are experiencing charging failure or a shortened service life, several components could be at fault. Start by checking the lead-acid battery; it might be defective. Remove the battery and try powering the scale with a charging transformer to see if the battery is the issue. Also, the charging transformer itself could be the problem; try using a normal charging transformer. Other potential issues include defective components or a power circuit problem. Look for a blown fuse, and if found, replace it. Inspect components like D2/ Q1(D313)/U5 Q2/Q3/Q4 and replace any that are defective. The charge lamp may also be defective or have reversed polarity.
  • N
    nlewisSep 4, 2025
    How to fix a poor LCD display on Jadever JCL-30K Scales?
    • J
      jenniferlevySep 4, 2025
      If the LCD display on your Jadever Scales is poor, the LCD itself may be defective. After confirming there isn't a broken board line or short circuit between the LCD and other conducting objects, replace the LCD directly. Alternatively, a component or part may be defective; check CP19/LM2930 and replace any defective components. An IC (PT6554) related circuit fault could also be the cause; in this case, check the IC (PT6554) related circuit and replace the defective one.
  • J
    Jamie LawrenceSep 6, 2025
    What to do if my Jadever Scales are weighing incorrectly?
    • C
      Catherine DavisSep 6, 2025
      If your Jadever Scales are weighing incorrectly, the component LM2931, AD5530, or 4.9152M might be defective and require replacement. Another potential cause is a load cell malfunction, which would also require replacement.

Summary

Precautions

Setting Mode

Calibration

Single and Multi-point Calibration

Guide for calibrating the scale using single or multiple points.

Operation

Tare and Preset Tare

How to perform tare and preset tare operations.

Weight Limit Checking

Setting high and low limits for weight checking.

Quantity Limit Checking

Setting high and low limits for quantity checking.

Basic Counting

How to input unit weights and perform basic counting.

Sample Counting and ACAI

Performing sample counting and Automatic Counting Accuracy Improvement (ACAI).

Accumulation Functions

How to accumulate, display, and clear data.

Troubleshooting

Error Messages and Solutions

Common error messages and their solutions.

Exporting Data to PC

PC Connection Troubleshooting

U.KEY Connector

Jadever JCL-30K Specifications

General IconGeneral
BrandJadever
ModelJCL-30K
CategoryScales
LanguageEnglish

Related product manuals