EasyManua.ls Logo

Jadever JCL-30K - User Manual

Jadever JCL-30K
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(II)
JCL 0
Content
1. Introduction..1
2. Precaution....................................1
3. Before Using the Product
3-1 Unpacking and Checking....1
3-2 Installing Components.....1
3-3 Leveling the Scale........1
4. Product Introduction
4-1 Specifications & General Features 2
4-2 Front Panel 3
4-2-1 Display . ......3
4-2-2 Keyboard.........4
4-3 Power Supply.........5
5. Setting Mode
5-1 Function Setting....5
5-2 Parameters.6
6. Single and Multi-point Calibration....8
7. Operation
7-1 Weighing9
7-2 Tare & Preset Tare.9
7-3 Checking function
7-3-1 Upper & Lower Weight Limit Checking ..10
7-3-2 Upper & Lower Quantity Limit Checking ....11
7-4 Basic Counting
7-4-1 Entering a Known Unit Weight and Unit weight Memory.12
7-4-2 Sample Counting and ACAL.12
7-5 Accumulation, Accumulation Display and Accumulation Clear...13
7-6 Initialization of the Scale to Printer (Optional)....14
7-7.The Control from PC to Scale (Optional)15
8. Serial Interface
8-1 RS-232 Connector.15
9. Troubleshooting and Error Message....16

Other manuals for Jadever JCL-30K

Questions and Answers

  • S
    Stephen LeeSep 8, 2025
    Why doesn't the buzzer work on my Jadever JCL-30K Scales?
    • A
      ashleywilliamsSep 8, 2025
      If the buzzer on your Jadever Scales isn't working, Q11 or Q8 may be defective; check and replace them if necessary. Alternatively, the buzzer itself may be defective, or there could be a fault in the buzzer circuit, requiring replacement.
  • R
    Ryan HarrisSep 10, 2025
    How to troubleshoot keypad dysfunction on Jadever JCL-30K Scales?
    • C
      Carrie HoltSep 10, 2025
      If the keypad on your Jadever Scales is not functioning correctly, the keypad or keypad circuit might be faulty; check and replace them if needed. Another possible cause is a CPU or CPU program issue; in this case, check and replace the CPU. Additionally, component 74LS139 could be defective; check and replace it if necessary.
  • G
    George WeberSep 12, 2025
    What causes memory dysfunction in Jadever JCL-30K Scales?
    • C
      Carla MorrisonSep 12, 2025
      If your Jadever Scales are experiencing memory dysfunction, the component 24C02, R29, R30, R31, or CP18 may be defective. Check these components and replace any that are faulty.
  • A
    andersonelizabethSep 13, 2025
    Why do I get messy code in printouts from my Jadever JCL-30K?
    • M
      meganfloydSep 13, 2025
      If you are getting messy code in the printouts from your Jadever Scales, it could be due to a wrong setting. Check and reset the external device, baud rate, and print mode. The RS-232 board could also be defective, so check and replace it if necessary. A bad connection between the RS-232 board and the main board could also be the problem; check and replace the wire connection. Finally, the external device itself may be defective and require maintenance or replacement.
  • C
    Caleb GarrisonSep 15, 2025
    What to do if the LCD backlight on my Jadever Scales has no function?
    • M
      Mr. John SnyderSep 16, 2025
      If the LCD backlight on your Jadever Scales is not functioning, the LCD backlight itself may be defective and require replacement. Alternatively, a component may be defective; check and replace Q9, CPU, P71, R72, R73, R74, R75, and R76.
  • B
    Brenda LambertSep 18, 2025
    What does the battery symbol mean on my Jadever JCL-30K?
    • S
      Samantha MaxwellSep 18, 2025
      If a battery symbol appears on your Jadever Scales, it could indicate insufficient cell voltage. Try recharging the battery. If the voltage of the battery is lower than 5.7V and the battery indication lamp is still green, replace the rechargeable battery immediately. A defective component could also be the cause; check and replace R34, R35, R36, and Q10. Finally, a bad connection between R34 and LM2930 could be the issue; repair the wire connection between these components.

Summary

Precautions

Setting Mode

Calibration

Single and Multi-point Calibration

Guide for calibrating the scale using single or multiple points.

Operation

Tare and Preset Tare

How to perform tare and preset tare operations.

Weight Limit Checking

Setting high and low limits for weight checking.

Quantity Limit Checking

Setting high and low limits for quantity checking.

Basic Counting

How to input unit weights and perform basic counting.

Sample Counting and ACAI

Performing sample counting and Automatic Counting Accuracy Improvement (ACAI).

Accumulation Functions

How to accumulate, display, and clear data.

Troubleshooting

Error Messages and Solutions

Common error messages and their solutions.

Exporting Data to PC

PC Connection Troubleshooting

U.KEY Connector

Jadever JCL-30K Specifications

General IconGeneral
BrandJadever
ModelJCL-30K
CategoryScales
LanguageEnglish