(II)
JWL 0
CONTENTS
Appendix 1: printing format (Optional)
Appendix 2Exporting data to PC in the form of EXCEL
1. Introduction………………………………….………………………………………………..
1
2. Precautions…………………………………….……………………………………………..
1
3. Before Using the Product
3-1 Unpacking and Checking……………………………………………………………………….
3-2 Installing Components ………………………………………..………………………………..
3-3 Leveling the Scale………………………………………………..……………………………..
1
1
1
4. Product Introduction
4-1 Specifications & General Features …………………………………...................................
4-2 Front Panel …….……………………………………………………………………………….
4-2-1 LCD display…………………………………………………………………………………
4-2-2 Keyboard………………………………………………………………………………………
4-3 Power Supply……………………………………………………………………………………
2
3
3
4
5
5. Function Setting and Description of Parameter Values
5-1 Function Setting ………………………………………………………………………………..
5-2 Description of Parameter Values…………………………………………………………..
5
6
6. Calibration……………………………………………………………………………………
8
7. Operation
7-1 weighing …………………………………………………………………………………………
7-2 manual tare &preset tare…………………………………………………………………........
9
10
7-3 check weighing………………………………………………………………………………….
7-4 Simple Counting…………………………………………………………………………………
7-5 Accumulation, Accumulation Display and Accumulation Clearing…………………………
7-6 Printer initialization by the indicator operation………………………………………………..
7-7 Input commands………………………………………………………………………………..
8. Serial Interface
8-1 Diagram………………………………………………………………………………………..
10
11
12
12
13
13
9. Troubleshooting and Error Message………………………………………………
14

Questions and Answers

  • I
    isaiahsellersAug 13, 2025
    What to do if Jadever Scales show wrong calibration weights?
    • V
      Victoria WallAug 13, 2025
      If your Jadever Scales display an error related to calibration weights, ensure that you are using the correct weights, matching the calibration value to the full load.
  • M
    Marc PalmerAug 17, 2025
    What to do if Jadever Scales show overload condition?
    • H
      Holly ProctorAug 17, 2025
      If your Jadever Scales indicate an overload condition, remove the weight from the pan that exceeds the scale's capacity.
  • D
    David ScottAug 21, 2025
    What to do if Jadever Scales exceed tare or pre-tare range?
    • D
      Dr. Ian JimenezAug 21, 2025
      If Jadever Scales exceed the tare or pre-tare range, ensure that the tare value is above zero and does not exceed the full load capacity.
  • A
    andrew36Aug 25, 2025
    What to do if Jadever JWL-1.5K exceed the initial zero point?
    • J
      jamiehallAug 25, 2025
      If your Jadever Scales exceed the initial zero point: 1. Check the scale pan for any foreign objects and remove them. 2. If the issue persists, it may indicate a load cell failure, requiring replacement or professional service.
  • T
    thomasduncanAug 28, 2025
    How to fix EEPROM failure in Jadever JWL-1.5K?
    • R
      Robert EdwardsAug 28, 2025
      If you encounter an EEPROM failure with your Jadever Scales, re-solder the EEPROM.
  • A
    angelrojasSep 1, 2025
    What to do if the accumulated number of weighments exceeds the display range on Jadever JWL-1.5K?
    • A
      Amy RamirezSep 1, 2025
      If the accumulated number of weighments exceeds the display range on your Jadever Scales, delete the excess weighments.
  • E
    emilyjacobsSep 4, 2025
    What to do if Jadever JWL-1.5K Scales lower limit is higher than upper limit?
    • S
      Scott SavageSep 5, 2025
      If the lower limit is higher than the upper limit on your Jadever Scales, re-enter the upper limit and lower limit settings.
  • A
    Annette ArmstrongSep 8, 2025
    What to do if Jadever Scales exceed the A/D resolution range?
    • J
      Jose BlackSep 8, 2025
      If your Jadever Scales exceed the A/D resolution range: 1. Check for A/D failure and replace the A/D if necessary. 2. If the problem persists, it may indicate a load cell failure, requiring replacement or professional service.

Summary

Introduction and Safety

2. Precautions

Essential safety guidelines and warnings for operating the weighing indicator.

Scale Configuration and Operation

5. Function Setting and Parameter Values

Guide to setting scale functions and understanding various parameter values.

5-1 Function Setting

Procedure for entering and navigating the function setting menu.

5-2 Description of Parameter Values

Detailed explanation of various parameter settings (P00-P07) for the scale.

6. Calibration

Procedure for calibrating the weighing indicator for accurate measurements.

7. Operation

Instructions for performing common operations with the weighing indicator.

7-1 Weighing

Basic steps for performing weighing operations on the scale.

Technical Interface and Troubleshooting

9. Troubleshooting and Error Messages

Common error messages and their corresponding problems and solutions.

Jadever JWL-1.5K Specifications

General IconGeneral
Capacity1.5 kg
Division/Readability0.1 g
DisplayLCD
Auto Power OffYes
Power SupplyAC Adaptor (12V/500mA) or 6 x AA Batteries
Unitsg, oz, ct, dwt