Page 7 WEIGHING SCALE
2. Troubleshooting
When Err. Msg. Troubleshooting
Power on
Err2
Check and remove any object from weighing pan or malfunction of LOAD CELL
Power on
Err3
Check if A/D or LOAD CELL malfunctions
Power on
Err4
Beep alert. Switch power off and power on again, or perform calibration
Power on Battery symbol Charge the battery with power on
Operating at
normal
weighing
mode
Err5
Checking if the weighing object is over the max. capacity +9e
Calibrating
Err6
Change weight
APPENDIX 2:
RS-232 OUTPUT FORMAT
Baud Rate : 2400, 4800, 9600
Data Bit : 8
Parity : N ( None )
Stop Bit : 1
Code : ASCII
Bit Format :
LSB MSB
0 1 2 3 4 5 6 7 8
Start
Bit
Parity
Stop
Bit
Data Format:
1. kg
G/
N
. W .
:
+/- k g
C
R
LF
weight
Example:
N.W. :+ 1.1375kg
T.W. :+ 0.0180kg
G. W. :+ 1.1555kg
2. g
G/
N
. W .
:
+/- g
C
R
LF
weight
Example:
N.W. :+ 1137.5g
T.W. :+ 18.0g
G. W. :+1155.5g
3. lb