H0661800_REVC
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/
operator of this equipment.
ENGLISH | FRANÇAIS | ESPAÑOL
INSTALLATION AND
OPERATION MANUAL
Jandy
VS FloPro™ Variable-Speed Pumps
Product may differ from image shown
VSFHP085AUT
VSFHP085JEP
VSFHP165AUT
VSFHP165JEP

Table of Contents

Questions and Answers

  • B
    Bobby BlackAug 15, 2025
    What to do if my Jandy Water Pump will not start?
    • B
      Benjamin NguyenAug 15, 2025
      If your Jandy Water Pump isn't starting, ensure it's properly connected to high voltage. Also, check the low-voltage wiring between the pump and controller, correcting it if necessary. Verify that the pump DIP switches 3 and 4 are correctly set for your installation. Finally, check the controller for any fault messages and resolve the fault before proceeding.
  • N
    Nancy JacksonAug 18, 2025
    How to troubleshoot a Jandy VS FloPro VSFHP165AUT Water Pump cleaning/circulating system that is not operating correctly?
    • W
      William HarperAug 18, 2025
      If your Jandy Water Pump cleaning or circulating system isn't working right, start by checking and cleaning the skimmer baskets, pump basket, and other screens. Clean the filter as needed. Then, check and adjust the valve positions.
  • I
    Isabella CruzAug 21, 2025
    Why is the LCD on my Jandy VS FloPro VSFHP165AUT Water Pump variable-speed controller not displaying information?
    • K
      Kevin GarciaAug 21, 2025
      If the LCD on your Jandy Water Pump variable-speed controller isn't displaying information, or the pump LEDs aren't lit, check the DIP switch settings. Ensure pump DIP switches 1 and 2 are both ON if the controller is a JEP-R, and both OFF if it's a PDA, AquaLink RS, or AquaLink Z4. Also, inspect the low-voltage wiring between the pump and controller, correcting it if necessary.
  • J
    Jose BrewerAug 25, 2025
    Why are there bubbles in my Jandy VS FloPro VSFHP165AUT Water Pump basket?
    • M
      Mitchell JohnsonAug 25, 2025
      Bubbles in the Jandy Water Pump basket usually indicate air in the system. Check the pool or spa water level to ensure it's adequate, preventing air from being drawn into the suction piping. Also, turn off the pump and inspect the lid seal for cracks or gaps. Clean the lid seal and the mating surface of the housing. Apply a small amount of silicone lubricant to the lid seal. Hand-tighten the lid to ensure an airtight seal.
  • J
    Jeffery DayAug 27, 2025
    Why does my Jandy VS FloPro VSFHP165AUT get hot and shut off?
    • A
      Andrea StoneAug 27, 2025
      If your Jandy Water Pump overheats and shuts off, ensure there's enough space around the motor for air circulation to keep it cool. It is also recommended to have a qualified electrician check for loose connections and verify the voltage at the pump motor while it's running. If the voltage isn't within 10% of the motor's data plate rating, contact a qualified electrician or your local power service provider.
  • S
    Shelly SmithAug 30, 2025
    What to do if air leaks are still present in my Jandy VS FloPro VSFHP165AUT Water Pump?
    • A
      aarongarrettAug 30, 2025
      If air leaks persist in your Jandy Water Pump, check the suction side piping union. While the pump is running, try tightening the union. If the leak continues, turn off the pump, loosen both unions, and slide the pump aside. Remove, clean, and reinstall both union o-rings. Reposition the pump and hand-tighten the union nuts. If they still don't seal, gently tighten them with tongue-and-groove pliers, being careful not to overtighten.
  • D
    David MccartySep 2, 2025
    Why does my controller display 'Pump not connected' for my Jandy VS FloPro VSFHP165AUT?
    • M
      Marissa FletcherSep 2, 2025
      If your controller displays 'Pump not connected' for your Jandy Water Pump, check the low-voltage wiring between the pump and the controller, correcting any issues. Also, ensure that the pump DIP switches 3 and 4 are properly set for your installation.
  • D
    Daniel PachecoSep 5, 2025
    Why is my Jandy VS FloPro VSFHP165AUT Water Pump leaking water between the motor and pump body?
    • R
      Riley RaymondSep 6, 2025
      Leakage between the motor and pump body in your Jandy Water Pump indicates a damaged or failed mechanical seal. The solution is to replace the seal.
  • K
    Kristen WarrenSep 8, 2025
    What could cause low pressure in my Jandy Water Pump if there is no debris blocking the impeller?
    • M
      michael36Sep 8, 2025
      If there is no debris blocking the impeller and the pressure is still low, it could be due to normal wear of the pump impeller and diffuser. Also, if the pump is newly installed, it could be an electrical problem. Another possible reason is that the pump seal is leaking air.
  • M
    mccallmichaelSep 12, 2025
    What should I do if a fault message appears on my Jandy VS FloPro VSFHP165AUT Water Pump controller display?
    • B
      Bethany HuntSep 12, 2025
      If a fault message appears on your Jandy Water Pump controller display, view the fault message on the controller and correct the fault before proceeding.

Summary

Jandy VS FloPro Safety Instructions

General Safety Precautions

General safety precautions for electrical equipment installation and use.

Pool Pump Suction Entrapment Prevention

Guidelines to minimize risk of injury from suction hazards in pools, spas, and hot tubs.

Jandy VS FloPro Installation Information

Electrical Installation Procedures

Details voltage checks, wiring, and connections for proper pump operation.

Jandy VS FloPro Bonding and Grounding

Bonding and Grounding Requirements

Requirements and methods for bonding and grounding the pump and pool system components.

Jandy VS FloPro Electrical Wiring

Electrical Wiring Best Practices

Proper grounding, wire sizing, and connection of electrical power supply to the pump.

Jandy VS FloPro Controller Installation

Jandy VS FloPro JEP-R Remote Mounting

Jandy VS FloPro JEP-R Wiring

Jandy VS FloPro DIP Switch Settings

VS FloPro Pump DIP Switch Configuration

Explains the function of DIP switches for selecting pump address and controller type.

Jandy VS FloPro Pressure Testing

Conducting System Pressure Tests

Procedure for pressure testing the system with water, emphasizing safety and air removal.

Jandy VS FloPro Operation and Start-up

Jandy VS FloPro Service and Maintenance

Jandy VS FloPro Winterizing Procedures

Jandy VS FloPro Troubleshooting

Troubleshooting and Repair Guide

Common symptoms, possible causes, and solutions for pump operation issues.

Jandy VS FloPro Technician Maintenance

Jandy VS FloPro Performance Curves

Jandy VS FloPro VSFHP165AUT Specifications

General IconGeneral
ModelVS FloPro VSFHP165AUT
CategoryWater Pump
TypeVariable Speed
Horsepower1.65 HP
Voltage230V
PhaseSingle Phase
Speed SettingsVariable Speed
Wet End MaterialThermoplastic
Motor TypePermanent Magnet
Control InterfaceDigital
Warranty3 Years
Energy EfficiencyENERGY STAR Certified

Related product manuals