WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state or
local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment
installation and maintenance so that all of the instructions in this manual can be followed exactly. Before
installing this product, read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage, personal injury, or death.
Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/
operator of this equipment.
INSTALLATION AND
OPERATION MANUAL
VSFHP185DV2A(S)
VSFHP270DV2A(S)
VSPHP270DV2A(S)
Jandy
Variable-Speed Pumps
ENGLISH | FRANÇAIS | ESPAÑOL
H0707401 REVB
VSSHP220DV2A(S)
VSSHP270DV2A(S)

Table of Contents

Questions and Answers

  • M
    Martin BaileyAug 3, 2025
    What to do if my Jandy VS PLUSHP 2.7 HP Water Pump motor won't start?
    • A
      Amy HamiltonAug 3, 2025
      First, have a certified professional check the voltage on the main power terminal with the breaker on, ensuring it's within 10% of the motor's rating. Then, power cycle the motor by turning off the main breaker, waiting at least 5 minutes before restoring power. Also, inspect the RS-485 connection, checking for secure connections, corrosion, and any broken wires. Ensure the DIP switches 3 and 4 are in the OFF position. Finally, verify that the motor is scheduled to turn on at the current time according to the controller's settings.
  • E
    Erin GreenAug 7, 2025
    How to test Jandy VS PLUSHP 2.7 HP drive with RS-485 jumper method?
    • M
      morganvincentAug 7, 2025
      Using small sections of 22 AWG wire, jump pins 1 to 3 and 2 to 4. Re-install the connector and attach the access cover. Apply power to the motor. The motor should spin at 2600 RPM indefinitely. If the motor works, there is a problem with the RS-485 line or with the controller.
  • K
    kathryn17Aug 11, 2025
    How to configure DIP switches on Jandy VS PLUSHP 2.7 HP?
    • J
      Jessica OrtizAug 11, 2025
      The variable speed drive has two DIP switches; 3 and 4. These must both be in the OFF position for Pump 01. This is the configuration for all controllers that are not automation and the first pump for automation. If more than one variable speed pump is being controlled with an automation system, they must be in the proper configuration. Refer to the DIP switch section of the manual to configure the other motors.
  • B
    Betty JacksonAug 15, 2025
    Why does my Jandy Water Pump motor start but then shut off?
    • E
      Edwin GarzaAug 15, 2025
      Debris might be stuck between the impeller and the diffuser. To resolve this, have a certified professional check if the drive shaft is seized with all power off. You can perform a quick test by inserting a 5/16" allen wrench through the back of the fan housing and into the drive shaft, then manually spin it to check for seizing. If you find large amounts of debris, inspect your strainer basket for any breaks and replace it if needed.
  • D
    Dana PerryAug 20, 2025
    How to fix improper low voltage wiring on Jandy Water Pump?
    • S
      Shawn IngramAug 20, 2025
      Ensure the RS-485 connection is secure and free of broken wires. Inspect the low voltage wiring for corrosion; if found, cut off the wires and strip new leads, ensuring no broken wire pieces are inside the RS-485 connector. Also, verify the wiring of the RS-485 connector, ensuring the wire colors for pins 1-4 are Red, Black, Yellow, and Green.
  • C
    Craig SinghAug 25, 2025
    What to do if Jandy Water Pump motor experienced an error?
    • S
      Scott AdamsAug 25, 2025
      Power cycle the motor. A fault code may appear on the controller. To clear the error, turn off the main breaker connected to the motor and wait at least 5 minutes before restoring power. Ensure the voltage in the capacitors is completely drained for a proper power cycle.
  • P
    paula87Aug 29, 2025
    How to check broken low voltage wiring on Jandy Water Pump?
    • M
      michaelallenAug 29, 2025
      With all power off, use a multimeter set to Ohms/Continuity to check the continuity of each low voltage line from the motor side to the controller side. If necessary, replace the RS-485 wires completely.

Summary

Important Safety Instructions

Safety Instructions

General electrical safety precautions for installation and use.

Pool Pump Suction Entrapment Prevention Guidelines

Guidelines to prevent suction entrapment hazards for pool pumps.

General Description

Introduction

Overview of Jandy Variable Speed Pumps and their operation.

Product Dimensions

Specifications for pump dimensions and required clearance.

Product Specifications

Technical specifications including THP, WEF, Voltage, Watts, Amps, Union Size, Weight.

Product Contents

List of items included in the pump package.

Installation Information

Zero Clearance TEFC Motor

Description of the motor's zero clearance feature and ventilation.

Plumbing and Location

Guidance on pump location, preparation, and pipe sizing.

Electrical Installation

Details on voltage checks, wiring, and GFCI requirements.

Bonding and Grounding

Requirements for bonding the pump motor and pool structure.

Electrical Wiring

Information on low voltage and high voltage wiring compartments and connections.

Pump Controller; Automation System Setup

Instructions for connecting pumps to Jandy controllers and automation systems.

Dipswitch Settings

Configuration settings for dip switches with local controllers and automation systems.

Auxiliary Relay Operation

Explanation of auxiliary relay functions and load connection requirements.

Conduct Pressure Test

Conduct Pressure Test

Procedure for performing a system pressure test, including safety warnings.

Replace Blue O-ring Before Pressure Testing

Steps to replace the blue O-ring on the pump lid for testing.

Operation

Start-up

Instructions for priming the pump, with variations for below and above water level.

Service & Maintenance

Removing the Pump Lid

Step-by-step guide on how to safely remove and replace the pump lid.

Clean Pump Basket

Procedure for inspecting and cleaning the pump filter basket.

Winterizing the Pump

Instructions for preparing the pump for winter to prevent freezing damage.

Troubleshooting and Repair

Motor wont start or controller not detected

Common causes and solutions when the motor fails to start or is not detected.

Motor starts but shuts off soon after

Troubleshooting steps for when the motor starts and then stops.

Motor gets hot and shuts off periodically

Diagnosing and resolving issues where the motor overheats and shuts down.

Service Technician Maintenance

Procedures for professional service and maintenance of the pump.

Product Specifications and Technical Data

Exploded Views

Illustrated breakdown of pump components for identification and parts reference.

Performance Curves

Graphs showing pump performance (head vs. flow rate) at different speeds.

Jandy VS PLUSHP 2.7 HP Specifications

General IconGeneral
ModelVS PLUSHP
Horsepower2.7 HP
TypeVariable Speed
Voltage230V
Efficiency RatingEnergy Efficient
Control TypeDigital
Warranty3 years
Wet End MaterialThermoplastic
Maximum Flow Rate150 GPM
Motor TypePermanent Magnet