EasyManua.ls Logo

Jandy VSPHP270JEP - User Manual

Jandy VSPHP270JEP
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
H0490000_REVE
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious
injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
ENGLISH
|
FRANÇAIS | ESPAÑOL
Jandy Pro Series
VS PlusHP Pumps
Models VSPHP270JEP
& VSPHP270AUT
INSTALLATION AND
OPERATION MANUAL

Questions and Answers

  • R
    rodriguezcrystalAug 14, 2025
    How to improve reduced flow in Jandy VSPHP270JEP Water Pump?
    • K
      Kelly PattonAug 14, 2025
      If your Jandy Water Pump has reduced flow, verify that the skimmer baskets, pump basket, and other screens are clean. Clean them if necessary. Also, check the filter and clean it if needed. Finally, check the valve positions and adjust them as necessary.
  • B
    Brandon TownsendAug 17, 2025
    What to do if Jandy Water Pump has no power?
    • S
      Shannon HernandezAug 17, 2025
      To address the issue of no power to your Jandy Water Pump, ensure that the pump is properly connected to high voltage. Refer to section “3.2 Electrical Installation” for guidance.
  • J
    Jessica SmithAug 25, 2025
    What to do if my Jandy VSPHP270JEP gets hot and shuts off?
    • M
      Mark BryantAug 25, 2025
      If your Jandy Water Pump gets hot and shuts off periodically, ensure there's enough space around the motor for air circulation to keep it cool. Also, have a qualified electrician check for loose connections and the voltage at the pump motor during operation. The voltage must be within 10% of the motor's data plate rating. If it's not, contact a qualified electrician or your local power service provider.
  • S
    scottmonroeAug 27, 2025
    How to fix air leaks in Jandy VSPHP270JEP?
    • K
      kathleen07Aug 27, 2025
      If you still have air leaks in your Jandy Water Pump, check the suction side piping union. While the pump is running, try tightening the union. If the air leak persists, turn off the pump, loosen both unions, and slide the pump aside. Remove, clean, and reinstall both union o-rings. Reposition the pump and secure the union nuts by hand-tightening them. If the unions still don't seal, gently tighten them with tongue-and-groove pliers, being careful not to overtighten.
  • G
    greenvanessaAug 31, 2025
    What to do if Jandy VSPHP270JEP Water Pump is leaking water?
    • K
      Kyle GonzalesAug 31, 2025
      If the Jandy Water Pump is leaking water between the motor and the pump body, this is caused by a damaged or failed mechanical seal. Replace the seal.
  • H
    holly29Sep 6, 2025
    How to fix low-voltage wiring in Jandy Water Pump?
    • K
      Katelyn BeardSep 6, 2025
      To resolve improper low-voltage wiring in your Jandy Water Pump, check the low-voltage wiring between the pump and the controller and correct it if necessary. Refer to section “3.2 Electrical Installation”.
  • J
    Jacob JohnsonSep 10, 2025
    How to configure address setting on Jandy VSPHP270JEP?
    • J
      jeffreycervantesSep 10, 2025
      To correct an improper pump address setting on your Jandy Water Pump, ensure that pump dip switches 3 and 4 are set properly for your installation. Both should be OFF for use with a Variable-Speed Controller, or set to the proper address when connected to an AquaLink® RS controller, an AquaLink PDA, or an AquaLink Z4. Refer to section “3.2.4.1 Install with AquaLink® controller”.
  • T
    Thomas MclaughlinNov 20, 2025
    Why are there bubbles in my Jandy VSPHP270JEP basket?
    • K
      Kimberly PughNov 20, 2025
      If bubbles are present in the Jandy Water Pump basket, it indicates air is in the system. First, check the pool or spa water level to ensure it's at the proper level, preventing air from being drawn into the suction piping. If the water level is normal, turn off the pump and unlock the lid by turning the locking ring counter-clockwise until 'START' aligns with the ports. Remove the lid and inspect for debris around the lid seal seat or improper installation of the lid seal, as these can cause air leaks. Clean the lid seal and replace it on the lid. Then, put the lid back on the pump housing, align 'START' with the ports, and turn the locking ring clockwise until 'LOCKED' aligns with the ports. Hand-tighten the lid to ensure an airtight seal, avoiding the use of tools. Finally, turn the pum...

Summary

Section 1. Important Safety Instructions

1.1 Safety Instructions

General safety precautions for electrical equipment installation and use.

1.2 Pool Pump Suction Entrapment Prevention Guidelines

Guidelines to minimize risk of injury from suction entrapment hazards in pools.

Section 2. General Description

2.1 Introduction

Overview of the Jandy Pro Series VS Plus HP pumps and manual.

2.2 Description

Details on the variable-speed pump and its ECM motor.

2.3 Preparation

Steps for checking carton contents and preparing for installation.

Section 3. Installation

3.1 Plumbing

Guidance on pump location and pipe sizing for installation.

3.1.3 Installation Recommendations

Specific advice for installing the pump and piping for optimal performance.

3.2 Electrical Installation

Requirements for correctly wiring the pump to power sources.

3.2.2 Bonding and Grounding

Procedures for proper electrical bonding and grounding of the pump.

3.2.3 Electrical Wiring

Step-by-step instructions for connecting electrical wiring to the pump motor.

3.2.4 Controller Options

Overview of compatible controllers for the VS PlusHP pump.

3.2.4.1 Install with AquaLink controller

Detailed steps for wiring and configuring the pump with AquaLink controllers.

3.2.4.2 Install with JEP-R variable-speed controller

Instructions for connecting and setting up the pump with the JEP-R controller.

3.2.4.3 Pump Dip Switch Settings

Explanation of dip switch functions for pump addressing and controller selection.

3.2.5 Auxiliary Load Operation

Information on the auxiliary load relay contact and its use.

Section 4. Operation

4.1 Remove Pump Lid

Step-by-step guide on how to safely remove the pump lid for maintenance.

4.2 Conduct Pressure Test

Procedures for safely pressure testing the system before operation.

4.3 Start-up

Instructions for priming and starting the pump after installation.

Section 5. Maintenance

5.1 Routine Maintenance

Procedures for regular cleaning and inspection of the pump basket and lid.

5.2 Winterizing the Pump

Steps to protect the pump from freezing during winter storage.

Section 6. Troubleshooting and Repair

Section 7. Product Specifications and Technical Data

7.1 Replacement Parts List

List of available replacement parts with their part numbers.

7.2 Exploded View

Diagram showing the pump components and their assembly.

7.3 Performance Curves

Graphs illustrating pump performance at different speeds and heads.

7.4 Physical and Operational Specifications

Details on pump models, HP, voltage, wattage, pipe size, and dimensions.

Jandy VSPHP270JEP Specifications

General IconGeneral
ModelVSPHP270JEP
CategoryWater Pump
TypeVariable Speed Pump
Horsepower2.7 HP
PhaseSingle Phase
Frequency50/60 Hz
Maximum Flow Rate150 GPM
Warranty3 years

Related product manuals