WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state or
local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment
installation and maintenance so that all of the instructions in this manual can be followed exactly. Before
installing this product, read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage, personal injury, or death.
Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/
operator of this equipment.
INSTALLATION AND
OPERATION MANUAL
VSFHP185DV2A(S)
VSFHP270DV2A(S)
VSPHP270DV2A(S)
Jandy
Variable-Speed Pumps
ENGLISH | FRANÇAIS | ESPAÑOL
H0707401 REVB
VSSHP220DV2A(S)
VSSHP270DV2A(S)

Table of Contents

Questions and Answers

  • M
    Michael BrooksAug 5, 2025
    What to do if my Jandy VSSHP270DV2A motor won't start?
    • W
      Wayne LeeAug 6, 2025
      First, have a certified professional check the voltage on the main power terminal with the breaker on, ensuring it's within 10% of the motor's rating. Then, power cycle the motor by turning off the main breaker, waiting at least 5 minutes before restoring power. Also, inspect the RS-485 connection, checking for secure connections, corrosion, and any broken wires. Ensure the DIP switches 3 and 4 are in the OFF position. Finally, verify that the motor is scheduled to turn on at the current time according to the controller's settings.
  • S
    Sarah GarciaAug 10, 2025
    How to test Jandy Water Pump drive with RS-485 jumper method?
    • S
      Shelby CoxAug 10, 2025
      Using small sections of 22 AWG wire, jump pins 1 to 3 and 2 to 4. Re-install the connector and attach the access cover. Apply power to the motor. The motor should spin at 2600 RPM indefinitely. If the motor works, there is a problem with the RS-485 line or with the controller.
  • M
    Michael HughesAug 14, 2025
    How to configure DIP switches on Jandy Water Pump?
    • J
      Jeffrey CruzAug 14, 2025
      The variable speed drive has two DIP switches; 3 and 4. These must both be in the OFF position for Pump 01. This is the configuration for all controllers that are not automation and the first pump for automation. If more than one variable speed pump is being controlled with an automation system, they must be in the proper configuration. Refer to the DIP switch section of the manual to configure the other motors.
  • C
    Cheryl MoyerAug 18, 2025
    Why does my Jandy VSSHP270DV2A Water Pump motor start but then shut off?
    • D
      davidlambertAug 18, 2025
      Debris might be stuck between the impeller and the diffuser. To resolve this, have a certified professional check if the drive shaft is seized with all power off. You can perform a quick test by inserting a 5/16" allen wrench through the back of the fan housing and into the drive shaft, then manually spin it to check for seizing. If you find large amounts of debris, inspect your strainer basket for any breaks and replace it if needed.
  • A
    andreafreemanAug 23, 2025
    How to fix improper low voltage wiring on Jandy VSSHP270DV2A Water Pump?
    • M
      Marilyn HenryAug 23, 2025
      Ensure the RS-485 connection is secure and free of broken wires. Inspect the low voltage wiring for corrosion; if found, cut off the wires and strip new leads, ensuring no broken wire pieces are inside the RS-485 connector. Also, verify the wiring of the RS-485 connector, ensuring the wire colors for pins 1-4 are Red, Black, Yellow, and Green.
  • M
    Meagan Gardner MDAug 27, 2025
    What to do if Jandy Water Pump motor experienced an error?
    • T
      Thomas HughesAug 27, 2025
      Power cycle the motor. A fault code may appear on the controller. To clear the error, turn off the main breaker connected to the motor and wait at least 5 minutes before restoring power. Ensure the voltage in the capacitors is completely drained for a proper power cycle.
  • R
    Robert SellersAug 31, 2025
    How to check broken low voltage wiring on Jandy Water Pump?
    • J
      Janice GonzalezAug 31, 2025
      With all power off, use a multimeter set to Ohms/Continuity to check the continuity of each low voltage line from the motor side to the controller side. If necessary, replace the RS-485 wires completely.

Summary

Important Safety Instructions

General Safety Precautions

Essential safety guidelines, warnings, and hazard information for pump installation and use.

Suction Entrapment Prevention

Guidelines to prevent serious injury or death from suction entrapment hazards.

Installation Information

Plumbing Installation

Guidance on pump location, pipe sizing, and installation recommendations.

Electrical Installation and Wiring

Instructions for safe electrical connections, grounding, bonding, and wiring.

Dry Contact Operation

Conducting Pressure Tests

Detailed steps for safely performing pressure tests on the system.

Pump Operation

Service and Maintenance

Troubleshooting and Repair

Service Technician Maintenance

Procedures for qualified technicians performing pump maintenance and repairs.

Jandy VSSHP270DV2A Specifications

General IconGeneral
ModelVSSHP270DV2A
CategoryWater Pump
TypeVariable Speed
Horsepower2.7 HP
Voltage230V
PhaseSingle Phase
Frequency60 Hz
Warranty3 Years
ControlDigital