9
Set the stitch pattern to “ ”. The standard needle drop position should be at center of the needle plate hole.
Select zigzag stitch “ ”, and set the stitch width at “5.0”.
The clearance between the needle and the edge of the needle hole in the needle plate should be at least
0.2 mm on either side. If not, adjust as follows:
1. Turn the power switch on. Set the stitch pattern to “ ”, and select zigzag stitch “ ”.
Check that the needle drop position.
2. If the needle drop position is not correct, turn the power switch off and remove the face cover.
Loosen the hexagonal socket screw 3 x 4. Adjust the needle drop position by turning the eccentric pin.
Note:
Make sure to adjust the eccentric pin between the range of downward direction.
3. Tighten the socket screw 3 x4.
Attach the face cover.
Note:
Check the hook timing after this adjustment.
Needle Drop Position
Eccentric pin
Socket screw 3 x 4
Needle hole
0.2 mm or more
0.2 mm or more
A=B
A
B
Eccentric
Rotation center
Between the range of
downward direction