EasyManua.ls Logo

Janome JR3000 Series - Profinet; Connector Diagram; Network Status; Module Status

Janome JR3000 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
External Control (I/O / Fieldbus) 78 DESKTOP ROBOT JR3000
7.6
PROFINET
7.6.1
Connector Diagram
This module has four status LEDs and two Ethernet connectors.
# Name
1 Network Status (NS) (LED)
2 Module Status (MS) (LED)
3 Ethernet Connector (Port 1)
4 Ethernet Connector (Port 2)
5, 6 Link/Activity (LED)
7.6.2
Network Status
Status Details
OFF Not supplied with power
Green Online (RUN)
Green blinking Online (STOP)
7.6.3
Module Status
Status Details
OFF Module is initializing or not supplied with power
Green Communicating normally
Green 1 flash Diagnostic event (s)
Green blinking (1 Hz) Access from engineering tool
Red Stopped due to a fatal error
Red 1 flash Configuration error
Red 2 flash IP address is not set
Red 3 flash Station name is not set
Red 4 flash Internal error
7.6.4
Link/Activity
Status Details
OFF Network cable is not connected
Green Link is established but with no communication
Green blinking Link and communication are established