Please contact the maintenance
personnel of
Shenzhen JASIC Technology CO., Ltd.
When the temperature is too low, leave the
machine work for while, wait for the
temperature in the machine to rise and fan
to rotate normally. If it does not work,
replace the fan.
(1) Make sure that the valve of argon
cylinder has been opened and there is
enough pressure. Generally, if the
pressure in the cylinder is lower than 0.5
MPa, it is necessary to refill the cylinder.
⑵ Check whether the argon flow rate is
normal. You can choose different flow rates
according to different welding current
conditions, but too low a flow rate may lead
to insufficient shielding gas to cover all
weld joints. It is suggested that the argon
flow rate should no less than 5L/min no
matter how small the current is.
(3) Check whether the gas passage is
leaking, or whether the gas purity is too
low.
(4) Check whether there is strong ambient
air flow in the environment.
(1) Replace tungsten electrode with higher
quality.
⑵ The tungsten is contaminated
(3) Increase the post flow time to avoid
tungsten oxidation.