17
Autoranging Digital Multimeter
Range
200.0
2.000k
20.00k
200.0k
2.000M
20.00M
Test Current
0.3mA typical
Audible threshold: Less than100 Test current: <0.3mAΩ
Overload protection: 250V AC/DC rms.
Accuracy
±(1.5% + 4 digits)
±(1.2% + 2 digits)
±(1.5% + 2 digits)
±(2.0% + 3 digits)
Accuracy
±(1.0% + 5 digits)
Resolution
0.1
1
10
100
1k
10k
Resolution
1mV
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Function
Resistance
Input Protection: 250V dc or 250V ac rms.
Function
Diode Test
Open circuit voltage: 1.5V dc typical
Overload protection: 250V AC/DC rms.
Audible
Continuity
Accuracy is given at 18 to 28°C (65 to 83°F), less than 70%RH.