16
Autoranging Digital Multimeter
7.Specifications
7-
1.Technical Specifications
Range
200.0mV
2.000V
20.00V
200.0V
600V
2.000V
20.00V
200.0V
600V
200.0µA
2000µA
20.00mA
200.0mA
200.0µA
2000µA
20.00mA
200.0mA
Accuracy
±(0.5% + 4 digits)
±(1.2% + 5 digits)
±(1.5% + 5 digits)
±(1.2% + 4 digits)
±(1.5% + 3 digits)
±(2.0% + 4 digits)
±(1.0% + 3 digits)
±(1.5% + 3 digits)
±(1.5% + 3 digits)
±(1.8% + 3 digits)
Resolution
0.1mV
1mV
10mV
100mV
1V
1mV
10mV
100mV
1V
0.1µA
1µA
10µA
100µA
0.1µA
1µA
10µA
100µA
Function
DC Voltage
Input Impedance: 10MΩ
Maximum Input: 600V AC/DC rms
AC Voltage
(50 to 60Hz)
Input Impedance: 10MΩ
Maximum Input: 600V AC/DC rms.
DC Current
Overload Protection: 0.2A/600V
Maximum Input: 200mA DC or 200mA AC rms on µA/mA ranges.
AC Current
Overload Protection: 0.2A/600V
Maximum Input: 200mA DC or 200mA AC rms on µA/mA ranges.