Please see operator manual for full details.
1
2 3
4 5 6
7
8
Raise Pod Arm
Ensure the hydraulic isolation
lever (left hand arm rest) is in
the raised position.
Engage Seat Belt
Engage seat belt (A) into
latch (B) before starting
machine.
Power Machine On
Disarm Immobiliser
Start Motor
Lower LH Arm Rest
Press 2 GO Button
Operate Machine
Insert key in to ignition
switch, and turn to position I.
The instrument panel will
illuminate.
If fitted, disarm by entering
PIN code using the switch
panel buttons. Confirm
code by pressing the tick
button.
Note: switch panel buttons
will all be illuminated red
and instrument panel will
display a padlock symbol if
immobiliser is fitted and
armed
Lower the LH arm rest to
activate the hydraulics.
Note: If 2 GO enabled go to
step 8, if not go to step 9
A – Handle
B – LH arm rest
If enabled
press 2 GO button
(A) to activate hydraulics.
Instrument panel will
illuminate (B) when active.
All controls are now active
and the machine is now
ready to use.
START UP SEQUENCE
A – Handle
B – LH arm rest
19C-1E
16
A
B
A
B
A
B
A
B
Turn key in ignition switch to
position III and hold until the
motor running indicator light
illuminates.