Issue / FAQ Resolution / Answer
500hrs Greasing - Do the bushes
need to be replaced at 500hrs?
No, just grease and continue work
500hrs Greasing - After the first
500hrs do the bushes then need
greasing daily?
No, the bushes wont need greasing until the next 500hrs
500hrs Greasing - Without daily
greasing what cleans all the dirt
out of the bush?
Machine is fitted with one way seals stopping dirt entering
the bush but allowing old grease out when greasing
How do I switch from ISO to SAE
control patterns?
The control pattern change-over switch is located under
the operator station.
Position 1 = SAE
Position 2 = ISO
Always refer to the in cab display for confirmation of
control pattern selection.
How do I activate continuous
auxiliary flow?
To activate constant flow, select right hand finger button
on the right hand joystick. Please refer to page 15 for
joystick control layout.
What are the max flows and
pressures of the Auxiliary circuits?
28
TROUBLESHOOTING / FAQS
19C-1E
Aux Flow (L/min)
Aux Pressure bar
(psi)
19C-1e 32 200 (2,898.5)

Other manuals for jcb 19C-1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jcb 19C-1E and is the answer not in the manual?

jcb 19C-1E Specifications

General IconGeneral
Battery TypeManganese laminated Lithium-ion
Battery Rated Capacity14.8 kWh (3 Pack) 19.8 kWh (4 Pack)
ChargingOn-board charger with direct connection from AC mains power supply
Charging Time110V – 12 hrs 230V – 8 hrs
Fast Charging (Optional)Off-board charger, with connection to 415V 3-Phase supply Charging time <2 hrs
System Voltage48V
Motor TypeAC permanent magnet
Motor Power7 kW continuous 20kW peak
Operating ModesL – 1200rpm G – 1600rpm H – 1800rpm Auto Kick Up – 2300rpm, 2 speed tracking only
Thermal LimitationsOperation: -10oC to +46oC Charging: -10oC to +40oC