Please see operator manual for full details.
Issue / FAQ Resolution / Answer
500hrs Greasing - Do the bushes
need to be replaced at 500hrs?
No, just grease and continue work
500hrs Greasing - After the first
500hrs do the bushes then need
greasing daily?
No, the bushes wont need greasing until the next 500hrs
500hrs Greasing - Without daily
greasing what cleans all the dirt
out of the bush?
Machine is fitted with one way seals stopping dirt entering
the bush but allowing old grease out when greasing
How do I switch from ISO to SAE
control patterns?
The control pattern change-over switch is located under
the operator station.
• Position 1 = SAE
• Position 2 = ISO
Always refer to the in cab display for confirmation of
control pattern selection.
How do I activate continuous
auxiliary flow?
To activate constant flow, select right hand finger button
on the right hand joystick. Please refer to page 15 for
joystick control layout.
What are the max flows and
pressures of the Auxiliary circuits?
28
TROUBLESHOOTING / FAQ’S
19C-1E
Aux Flow (L/min)
Aux Pressure bar
(psi)
19C-1e 32 200 (2,898.5)