EasyManua.ls Logo

jcm-tech RB3 T868 - Receiver Adjustment and Operating Modes; SW1: Interference Detector Settings; SW2: Operating Mode Selection; SW3: R3 Functionality

jcm-tech RB3 T868
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjustment of the receiver / Operating modes
ON
Any change in the configuration of the switches needs a
reprogramming of the system (see "Programming").
OFF
Interference detector
SW1
7 s The equipment is switched to safety state after 7s.
265
ms
The equipment is switched to safety state after 265ms.
Operating mode with optical safety edges
SW2
ON
In ON mode, only "always on" optical safety edges (OSE-
S7502B and OSE-S7502) are permitted, as the optical element
always is on.
WORK
In WORK mode, the optical elements are OFF meanwhile the
ATEST signal is active. So it is necessary to disconnect this
ATEST signal during the door movement.
With resistive or mechanical safety edges, the selector does not work because it is
not necessary to activate the sensors.
R3 function
SW3
Low
battery
In low battery indication mode, the relay contact is closed
when any of the transmitters has an insufficient level of bat-
tery.
Alarm
In ALARM mode, the relay contact is closed to indicate that
any of the safety edges stored in the receiver are active.
jcmtechnologies