EasyManua.ls Logo

JCM iVIZION User Manual

JCM iVIZION
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
iVIZION® Banknote Validator Operators Guide June, 2014 June, 2014
Part No. 960-100932R_Rev. A © 2014, JCM American, Corporation
16
1
Part No. 960-100932R_Rev. A
For the Americas & Oceania, E-mail: support@jcmglobal.com
For the UK, Ireland, Europe, Africa, Russia & Middle East, E-mail: support@jcmglobal.eu
For Asia E-mail: asiapactechsupport@jcmglobal.com
JCM is a registered trademark of JCM American Corporation. All other product names
mentioned herein may be registered trademarks or trademarks of their respective companies.
Furthermore, , ® and © are not always mentioned in each case throughout this publication.
Operators Guide
© 2014, JCM American, Corporation
Operators Guide
iVIZION
®
Banknote Validator
Preventive Maintenance Instructions
This Guide describes procedures for the cleaning and maintenance of the
iVIZION
®
Banknote Validator. For additional information, refer to Section 2 of
the iVIZION Operation and Maintenance Manual (JCM P/N 960-100929R).
iVIZION REFERENCE DIAGRAMS
Figure 1 identifies the iVIZION
Validator Head, Transport Unit and Cash Box.
Notes regarding iVIZION Components:
– Sensor locations are shown in yellow.
– Rollers are shown in blue.
– Drive Belts are shown in orange.
– Release levers are shown in green.
– Anti-stringing area is shown in red.
Figure 1 iVIZION Unit, Validator Head, Transport Unit and Cash Box
Typical iVIZION Components
iVIZION Validator Head
Typical iVIZION Unit
(fully assembled)
iVIZION Head and Transport Unit
iVIZION Transport Unit
(inverted)
iVIZION Cash Box
PERSONAL NOTES AND COMMENT AREA
Write any pertinent notes or comments regarding your particular installation
here.
Question and Answer IconNeed help?

Do you have a question about the JCM iVIZION and is the answer not in the manual?

JCM iVIZION Specifications

General IconGeneral
Power Supply12V DC
Note AcceptanceMulti-currency
Operating Temperature0°C to 50°C
Operating Voltage12V DC
ConnectivityUSB, RS-232
Operating Humidity30% to 85% RH
ProtocolsCCNet, MDB
Acceptance SpeedApproximately 2 seconds
Note OrientationAll four orientations
Storage Temperature-20°C to 60°C

Summary

iVIZION Validator Preventive Maintenance Introduction

iVIZION Reference Diagrams

Illustrates key components of the iVIZION Validator Head, Transport Unit, and Cash Box for reference.

Maintenance Preparation and Resources

Tools and Equipment for Maintenance

Lists necessary tools and cleaning supplies for proper maintenance of the iVIZION Banknote Validator.

Reference Manuals for iVIZION

Directs users to essential manuals for detailed operational and maintenance information.

Cash Box Preventive Maintenance Procedures

Cash Box Cleaning Steps (Monthly/12,000 Cycles)

Step-by-step instructions for cleaning the cash box sensors, gears, and interior surfaces.

iVIZION Preventive Maintenance Schedules

Monthly Maintenance Schedule (12,000 Cycles)

Details required monthly cleaning tasks for the Validator Head, Transport Unit, and Cash Box.

6-Month Maintenance Schedule (72,000 Cycles)

Specifies semi-annual inspection and cleaning tasks for the Validator Head, Transport Unit, and Cash Box.

Annual Maintenance Schedule (144,000 Cycles)

Outlines annual procedures including inspection, testing, and software verification for the unit.

Component Cleaning Procedures

Validator Head Cleaning (Monthly/12,000 Cycles)

Instructions for cleaning the Validator Head's bill path and optical sensor lenses.

Transport Unit Cleaning (Monthly/12,000 Cycles)

Procedures for cleaning optical sensors and the feed-in mechanism in the Transport Unit.

Validator Head Cleaning (6 Months/72,000 Cycles)

Details inspection and cleaning of drive belts, lenses, rollers, and dust removal for the head.

Transport Unit Cleaning (6 Months/72,000 Cycles)

Instructions for inspecting lenses, drive belts, and cleaning rollers in the Transport Unit.

Validator Head Cleaning (Annual/144,000 Cycles)

Refers to monthly procedures for annual cleaning of the Validator Head.

Transport Unit Cleaning (Annual/144,000 Cycles)

Covers annual procedures including inspection, gear cleaning, and testing for the Transport Unit.

General Unit Procedures and Inspection

General Unit Procedures (Annual/144,000 Cycles)

Covers reassembly, calibration, and statistic initialization after annual cleaning.

General Unit Procedures (6 Months/72,000 Cycles)

Involves reassembly, statistic initialization, and ensures the unit is ready for service.

Inspection Procedures

Details visual inspection for damage and checking performance statistics using JCM Tool Suite.

Inspection Procedures (6 Months/72,000 Cycles)

Focuses on checking statistics for error codes and performing a visual inspection of the unit.