3 Hardware and Installation
3.1 Environmental Conditions
No outdoor storage. Warehouses have to be well
ventilated and dry. Temperature from
-25°C up to +55°C
5°C -50°C environment,
(above 40°C, nominal current reduced to 6A)
10-90% non-condensing
No external air conditioning needed; integrated heat
sink.
3.2 Assembly and Installation
Assembly with two screws on an electrically
conductive rear wall e.g. the back wall of a switch
cabinet.
For a series mounting the distance between the
devices has to be at least 10mm and the distance to
the floor has to be at least 40mm.
We recommend mounting the devices in vertical
orientation with the 7-segment display at the top to
ensure a good cooling air circulation.
It is recommended to install the XENAX® servo
controller in a control cabinet and to connect the
motor cable to the protective earth using the
EMC shield clamp (Art. No. 130.09.00).