15
4.2.7 PLC I/O
Output
Signal
D-Sub
PLC Cable
PLC I/O
Source PNP: 24V/100mA, Sink NPN: open collect. 24V/400mA
Pin 1
white
Output 1 (0/24V)
Source PNP: 24V/100mA, Sink NPN: open collect. 24V/400mA
Pin 2
brown
Output 2 (0/24V)
Input
24V Input, Ri 31k
Pin 3
green
Input 1
24V Input, Ri 31k
Pin 4
yellow
Input 2
24V Input, Ri 31k
Pin 5
grey
Input 3
24V Input, Ri 31k
Pin 6
pink
Input 4
Enabling Power Stage
Activate the function with DIP-switch
DIP switch OFF
HW power stage enabling with 24V on Pin 9
Pin 9
black
Enable PWR / Input
DIP switch ON
Input open or 0V = power stage blocked
Always enabling power stage, Pin 9 inactive
(Standard configuration)
Power Output
2A
Pin 10
violet
GND
24V / 200mA
Pin 12
red-blue
+ 24V Output
ON
OFF