14
4.2.6 OPTIO Pulse/Dir, Second Encoder Channel
The pulse/Dir and second encoder channel are
deactivated by default. Both options can be ordered.
PULSE/DIRECTION CONTROL
Enter settings in menu setup / basic settings:
PULSE / DIRECTION CONTROL, MODE 2, optional
Parameter MODE and INC PER PULSE
Signal
D-SUB
PLC Cable
Socket PLC I/O / Analog
GND internal
Pin 7
blue
GND
Pull up 2,7kΩ to 5V, differential input 26LS32
Pin 15
white-yellow
PULS
Pull up 2,7kΩ to 5V, differential input 26LS32
Pin 13
white-green
DIRECTION
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32
Pin 12
red-blue
DIRECTION*
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32
Pin 14
brown-green
PULS*
ENCODER 2
Electronic gear, MODE 1, optional
Parameter SYNCH RATIO 10 = 1:1
Signal
D-Sub
PLC Cable
Socket PLC I/O / Analog
GND intern
Pin 7
blue
GND
5V intern
Pin 8
red
5V (Power encoder)
Pull up 2,7kΩ to 5V, differential input 26LS32
Pin 15
white-yellow
A
Pull up 2,7kΩ to 5V, differential input 26LS32
Pin 13
white-green
B
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32
Pin 12
red-blue
B*
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32
Pin 14
brown-green
A*