Disconnecting of hard plumbing or removal of counter tops or cabinets, etc.,
for servicing is not covered by warranty.
CHEMICAL INSTALLATION
All the chemical pumps, located on the control box at the top, are activated by a
timer. Priming switch above will help draw the product in each corresponding
lines. The BLEU tubing is for the rinse-aid, or drying agent. The RED tubing is for
the detergent, and the CLEAR tubing is for the sanitizing solution.
WARNING
Whenever manipulating chemicals, use appropriate protection (eyes
and hands) as these chemicals are corrosive.
Detergent:
High sequestrant alkaline solution
200 ppm
Sanitizer:
Chlorine solution (min. 120F, 49C) min: 50 ppm
(as NaOCl)
Iodine Solution (min. 75F, 24C) min: 12.5 ppm-
max: 25 ppm
Quaternary ammonium solution (min. 75F,
24C)min: 150 ppm - max:400 ppm
Rinse-Aid:
Low foam rinse-aid, surfactant isopropanol
50 ppm
See local health code for appropriate quantities and usage.
Contact your chemical representatives for calibration and supply.
Dertegent
Red Tube
Sanitizer
Clear tube
Rinse-Aid
Blue Tube
6
Priming
Switches