12.0 Troubleshooting
Lathe unplugged from wall, or motor.
Check all plug connections.
Fuse blown, or circuit breaker tripped.
Replace fuse, or reset circuit breaker.
Lathe does not come up
to speed.
Extension cord too light or too long.
Replace with adequate size and length cord.
Contact a qualified electrician.
Lathe vibrates
excessively.
Locate lathe on even floor.
Lathe not bolted to the floor
Bolt machine to the floor
Improve chucking length or diameter, support on
tailstock end
Re-sharpen or change tool
Reduce depth of cut or feed
Re-sharpen or change tool
Tailstock alignment is offset.
Align tailstock position.
Stand supporting surface must be flat. Shim if
needed
Reduce depth of cut or feed
Drill chuck or arbor
does not stay in place.
Dirt, grease, etc. on arbor, chuck, or
tailstock quill
Clean all mating surfaces thoroughly with a
cleaner-degreaser.
* WARNING: Some corrections may require a qualified electrician.
Table 1
13.0 Environmental Protection
Protect the environment.
Dispose all packaging material in an environmental friendly manner.
Dispose coolant in an environmentally friendly manner.
Your appliance contains valuable materials which can be recovered or recycled. Please leave it at a specialized institution.
14.0 Available Accessories
Refer to the JET price list.