Parameters
CR at end or ? CR at end
Get: CR at end or ? CR at end
Set: SFP,X or XX or XXX
9Jetco Torque Tools
Description
www.itorque.com
Get: CR at end or ? CR at end
Set: SEA,X or XXX, = 0 to 360, 0 = OFF
LIST OF ASCII COMMANDS
ExmapleCommand
Get:
Command: SET?<CR> or SET<CR>
Response: Setpoint Value
Set:
Command: SET,50.0<CR> = Set Setpoint to 50.0
Response: OK
Get: CR at end or ? CR at end
Set: SET,X or XXXXX
Get / Set SetpointSET
Command: BAT<CR>
Response: Battery Level in percent full.
Get:
Command: SFP?<CR> or SFP <CR>
Response: First Peak setpoint in A/D counts
Set:
Command: SFP,300<CR> = Set First Peak
setpoint to 300 counts. Range 1 to 999 counts.
Response: OK
Get:
Command: SEA?<CR> or SEA <CR>
Response: Angle Setpoint Value
Set:
Command: SEA,5<CR> = Set Angle Setpoint to 5
degrees
Response: OK
BAT
SFP
SEA
SWO
Get Battery Level
Get / Set First Peak A/D Count
Get / Set Angle Setpoint
Get / Set Auto Off Time
Get: CR at end or ? CR at end
Set: SWO,X or XX
Get:
Command: SWO?<CR> or SWO<CR>
Response: Auto off time in minutes
Set:
Command: SWO,10<CR> = Set Auto off time to
10 minutes. Range 1 to 30 minutes.
Response: OK