Terminal Block Wired For 230 Volt DELTA As Viewed
Through Rear Access Panel
FLW1916N_SVG1
L 1 L 2 L 3
1
3
4
2
6
8
9
10
10
10
5
7
1. Black Wire
2. White/Black Wire
3. Black/White Wire
4. White/Red Wire
5. Black/Red Wire
6. White Wire
7. Green/Yellow Wire
8. Earth/Ground - Power Cord
9. Neutral
10. 230 Volt
Figure 13
Install Appropriate Electrical Cord –
Washers W
ithout Heater
230 Volt, 50 Hertz, 10 Amp
Have a qualified electrician install appropriate electrical recepta-
cle.
To attach customer-supplied power cord:
1. Remove electrical access panel on rear of machine.
2. Remove plastic plug from hole in rear of machine.
3. Install strain relief, supplied with machine, in hole.
4. Put power cord through hole.
1. Install power cord through this hole after removing plastic
plug. Use strain relief supplied in accessories bag.
Figure 14
5. Attach power cord wires as shown in Figure 15 .
6. Tighten down the strain relief (supplied with unit) on the
power cord.
7. Reinstall access panel.
Installation
©