81
damaged.
3. Pipe
system
design is not
reasonable.
accordance
with water
pump or not.
3. If this
happen
frequently,
please contact
SUPPLIER.
Fault111
Temperature
sensor fault
Inverter shut
down.
Sensor not
connects
proper or
damaged.
If this happen
frequently,
please contact
SUPPLIER.
Fault112
Short circuit
fault
(Nonrecoverable
)
Inverter
shutdown,
non-recover
malfunction.
No
automatically
restart, only if
recharged.
Output wire
short circuit.
1. Please
check if there
is short circuit
in output wires.
2. If this
happen
frequently,
please contact
SUPPLIER.
Fault115
Output phase
lose
Inverter
shutdown and
will restart
automatically
after the fault
disappears.
Phase loss
in inverter
output.
1. Please
check if the
output wires
are proper
connected and
fixed.