5742639-JIM-C-0220
4 Johnson Controls Ducted Systems
Product Nomenclature
30JEZ CA2 A 1
A
1A A 1
Product Category & Efficiency
A = Direct Drive
1
B = Standard Static
D = High Static
Blower Option
Product Generation
1 = First Generation
C = Cooling Only
E = Electric Heat
Heat Type
H = 1 Stage Gas Aluminized Steel
J = 1 Stage Gas Stainless Steel
K = 1 Stage Low Nox Gas Aluminized Steel
L = 1 Stage Low Nox Gas Stainless Steel
05 = 5 KW
07 = 07 KW
10 = 10 KW
15 = 15 KW
20 = 20 KW
30 = 30 KW
05 = 50 MBH Input (1 Stage J03)
07 = 75 MBH Input (1 Stage J04) (2 Stage J03, J04, J05, JA6)
10 = 100 MBH Input (1 Stage J03, J05, JA6)
11 = 115 MBH Input (2 Stage J03)
12 = 125 MBH Input (1 Stage J04, J05, JA6) (2 Stage J04, J05, JA6)
Single Stage Natural Gas Heat Options
Heat Capacity
Nominal Cooling Capacity
J03 = 3 Ton
J04 = 4 Ton
J05 = 5 Ton
JA6 = 6 Ton
ZE = Pkg AC, Standard Efficiency
Voltage
1 = 208/230-1-60
2
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
Additional Options
1 = Std Throwaway Filter
2 = 2" Pleated Filters (Merv 8)
4 = Coil Guard (CG), STD Filter
5 = 2" Pleated Filter,CG
A = Std Cabinet
B = HDF(HingedFLTR/Tooless DR)
E = SSD (SST Drain Pan)
F = SSD, HFD
A = No Economizer
C = Economizer w/o Barometric RLF
F = Econ BAS Rdy w/o Barometric RLF
H = Motorized Damper
Outdoor Air Option
1 = No Service Options
2 = DSC (Disconnect Switch)
3 = NCO (Non-PWR Conv. Outlet)
4 = PCO (Powered Conv. Outlet)
5 = DSC,NCO
6 = DSC,PCO
A = No Sensors
B = PHM (Phase Monitor)
C = DFS (Dirty Filter Switch)
D = SSD (Supply Air Smoke DET)
E = RSD (Return Air Smoke DET)
F = PHM,DFS
G = PHM,SSD
H = PHM,RSD
J = DFS,SSD
K = DFS,RSD
L = SSD,RSD
M = PHM,DFS,SSD
N = PHM,DFS,RSD
P = PHM,SSD,RSD
Q = DFS,SSD,RSD
R = PHM,DFS,SSD,RSD
Refrigeration
A = Standard Refrigeration
B = ECC (E-Coat Cond Coil)
C = EEC (E-Coat Evap Coil)
F = ECC,EEC
Service Options
A = Stand Alone Smart Equipment™
B = Simplicity Lite
3
C = BACnet MSTP,Mdbs,N2 COM Card
D = CPC Control, DFS, APS
E = Novar ETM305IT Ctrl, DPS,APS
G = Novar UCM Ctrl, DFS, APS
H = Hnywll Excel 10 CTRL,DFS,APS
Controls Option
3-6 Ton Johnson Controls Model Number Nomenclature
Two Stage Natural Gas Heat Options
N = 2 Stage Gas Aluminized Steel
S = 2 Stage Gas Stainless Steel
P = 2 Stage Low Nox Gas Aluminized Steel
Q = 2 Stage Low Nox Gas Stainless Steel
00
00 = Cooling Only
Gas MBH Input (Unit Size Allowed)
Electric Heat (Unit Size Allowed)
Sensors
A
Cabinet Options
1. 3 - 5 ton only
3. 3 - 5 ton only
2. 3 - 5 ton only
2 = Second Generation
M = Verasys Single Zone
N = Verasys Change Over Bypass