© 2010 Johnson Controls, Inc.
2. If prompted, enter password (master is the factory default setting).
3. In the Service Control dialog box click All, then cl
ick Stop.
4. Click Done.
T
o quit monitoring of P2000 Services:
1. Right-click the “traffic signal” icon located in the system tray (right side of
the W
indows task bar), and select Quit from the menu.
T
o clean the database tables:
1. Go to St
art>Programs>Microsoft SQL Server 2005>SQL Server
Management Studio.
2. In the Connect to Server window select the regional server and click C
onnect.
3. Click the “Open File” button or go to File>Open>File.
4. Browse for the Clean (publi
cation name).sql files. The path is \Program
Files\Johnson Controls\Cardkey P2000\sql. Select one of the files, for
example, CleanEnterprise.sql, and click Open.