Table 39: 2 ton heating charging chart for XAH*36D and JH(E,V)T*(30,36)D in horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
600 Liquid pressure
(subcool)
316
(15)
359
(17)
397
(17)
294
(18)
337
(20)
375
(21)
284
(19)
326
(22)
364
(24)
268
(21)
309
(25)
347
(26)
245
(28)
284
(31)
322
(35)
234
(29)
273
(32)
310
(37)
218
(32)
259
(36)
294
(41)
800 Liquid pressure
(subcool)
284
(15)
322
(16)
361
(18)
267
(17)
305
(20)
343
(22)
258
(19)
296
(22)
334
(23)
245
(21)
283
(23)
319
(26)
228
(26)
267
(29)
303
(33)
220
(27)
258
(31)
292
(34)
208
(29)
243
(33)
279
(36)
1000 Liquid pressure
(subcool)
264
(13)
301
(16)
340
(18)
250
(17)
287
(19)
326
(21)
244
(18)
279
(20)
318
(23)
233
(20)
269
(23)
307
(26)
220
(25)
254
(27)
290
(31)
212
(26)
246
(29)
282
(32)
202
(27)
236
(30)
270
(33)
- Suction pressure 119 121 121 95 97 95 83 85 82 69 71 67 55 57 54 47 48 46 37 39 39
Table 40: 2 ton heating charging chart for XA(F,H)*(30,36)D and JH(E,V)T*(30,36)D in downflow and horizontal
right
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
600 Liquid pressure
(subcool)
325
(24)
369
(27)
407
(27)
302
(28)
346
(32)
385
(34)
291
(31)
335
(35)
374
(38)
275
(34)
318
(39)
356
(42)
261
(38)
303
(43)
343
(49)
249
(41)
291
(45)
331
(51)
232
(45)
276
(50)
314
(57)
800 Liquid pressure
(subcool)
304
(23)
346
(26)
387
(28)
287
(27)
327
(31)
367
(34)
276
(30)
318
(34)
358
(36)
263
(32)
303
(36)
342
(40)
242
(37)
283
(41)
321
(47)
234
(39)
273
(44)
310
(49)
220
(41)
258
(47)
296
(52)
1000 Liquid pressure
(subcool)
284
(21)
325
(25)
367
(28)
270
(27)
310
(30)
352
(34)
263
(28)
301
(33)
344
(37)
252
(33)
291
(37)
331
(41)
231
(36)
268
(40)
306
(45)
223
(38)
260
(43)
298
(47)
213
(40)
248
(44)
285
(48)
- Suction pressure 124 126 126 99 101 99 86 88 85 72 74 70 55 57 54 48 49 47 38 40 40
Table 41: 2.5 ton heating charging chart for XA(F,H)*(30,36)D and JH(E,V)T*(30,36)D in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
750 Liquid pressure
(subcool)
337
(14)
376
(15)
427
(15)
316
(17)
354
(18)
404
(19)
303
(18)
342
(19)
390
(21)
286
(20)
326
(21)
372
(23)
261
(22)
299
(23)
343
(26)
249
(23)
288
(25)
331
(27)
228
(23)
266
(25)
307
(28)
1000 Liquid pressure
(subcool)
300
(13)
338
(14)
384
(15)
282
(16)
320
(16)
365
(18)
273
(17)
311
(18)
355
(19)
260
(18)
297
(19)
341
(21)
241
(19)
282
(21)
319
(22)
231
(20)
268
(21)
308
(23)
218
(21)
254
(23)
294
(24)
1250 Liquid pressure
(subcool)
276
(14)
315
(13)
358
(14)
262
(15)
300
(15)
343
(17)
255
(16)
292
(17)
335
(18)
244
(17)
281
(18)
324
(19)
229
(18)
265
(19)
306
(20)
221
(19)
257
(20)
298
(21)
207
(19)
242
(21)
282
(21)
- Suction pressure 122 124 126 99 100 102 88 89 90 72 73 74 56 56 57 48 48 49 38 39 40
Table 42: 2.5 ton heating charging chart for XA(F,H)*(30,36)D and JH(E,V)T*(30,36)D in downflow and horizontal
right
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
750 Liquid pressure
(subcool)
357
(17)
398
(18)
452
(18)
334
(21)
375
(22)
428
(23)
321
(22)
362
(23)
413
(26)
303
(25)
345
(26)
394
(28)
276
(23)
316
(24)
363
(28)
263
(24)
305
(27)
350
(29)
241
(24)
281
(27)
325
(30)
1000 Liquid pressure
(subcool)
320
(17)
360
(19)
409
(20)
301
(21)
341
(21)
389
(24)
291
(22)
332
(24)
378
(25)
277
(24)
317
(25)
364
(28)
251
(21)
293
(23)
332
(24)
240
(22)
279
(23)
321
(25)
227
(23)
264
(25)
306
(26)
1250 Liquid pressure
(subcool)
296
(19)
338
(18)
384
(19)
281
(21)
322
(21)
368
(23)
274
(22)
313
(23)
359
(25)
262
(23)
301
(25)
348
(26)
243
(20)
281
(21)
324
(23)
234
(21)
272
(23)
316
(24)
219
(21)
256
(24)
299
(24)
- Suction pressure 120 122 124 98 99 101 87 88 89 71 72 73 55 55 56 47 47 48 38 38 39
Installation Manual: R-410A Outdoor Split-System Heat Pump - YH2F, THF2, RHP150 Series 25
Johnson Controls Ducted Systems