Table 43: 2.5 ton heating charging chart for XA(F,H)*48F and JH(E,V)T*42F in upflow, horizontal left, downflow and
horizontal right
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
750 Liquid pressure
(subcool)
342
(16)
382
(17)
433
(18)
320
(19)
359
(21)
410
(22)
308
(21)
347
(22)
396
(24)
290
(22)
330
(24)
378
(26)
261
(23)
298
(25)
343
(27)
249
(24)
287
(26)
330
(29)
230
(26)
268
(28)
310
(30)
1000 Liquid pressure
(subcool)
304
(17)
342
(17)
389
(18)
286
(19)
324
(20)
370
(21)
277
(20)
315
(21)
360
(22)
263
(21)
301
(23)
345
(24)
243
(21)
283
(23)
322
(24)
233
(22)
270
(24)
311
(25)
220
(24)
257
(25)
297
(27)
1250 Liquid pressure
(subcool)
280
(16)
319
(16)
362
(17)
266
(18)
304
(18)
347
(19)
259
(19)
296
(19)
339
(20)
247
(20)
285
(21)
328
(21)
232
(20)
268
(21)
310
(22)
224
(21)
260
(22)
301
(23)
209
(21)
244
(23)
284
(23)
- Suction pressure 122 124 126 99 100 102 88 89 90 72 73 74 56 56 57 48 48 49 38 39 40
Table 44: 3 ton heating charging chart for XA(F,H)*(30,36)D and JH(E,V)T*(30,36)D in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
900 Liquid pressure
(subcool)
344
(19)
386
(22)
433
(20)
323
(22)
363
(25)
409
(24)
311
(24)
351
(26)
395
(25)
294
(26)
333
(28)
377
(28)
271
(30)
311
(32)
353
(31)
260
(31)
299
(33)
340
(32)
239
(33)
277
(34)
317
(34)
1200 Liquid pressure
(subcool)
305
(18)
345
(19)
390
(20)
288
(21)
327
(22)
370
(23)
279
(22)
317
(24)
361
(25)
265
(24)
302
(25)
346
(27)
253
(27)
293
(30)
332
(30)
242
(29)
280
(30)
322
(31)
228
(30)
266
(32)
307
(33)
1500 Liquid pressure
(subcool)
282
(17)
322
(17)
366
(20)
268
(20)
307
(20)
351
(23)
260
(21)
299
(21)
343
(24)
250
(23)
287
(23)
331
(26)
238
(26)
275
(27)
318
(29)
230
(27)
267
(28)
310
(31)
218
(28)
254
(29)
296
(32)
- Suction pressure 119 121 121 94 97 98 83 85 86 68 70 72 53 55 57 46 47 49 37 38 39
Table 45: 3 ton heating charging chart for XA(F,H)*(30,36)D and JH(E,V)T*(30,36)D in downflow and horizontal
right
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
900 Liquid pressure
(subcool)
371
(24)
417
(28)
467
(25)
349
(28)
392
(32)
442
(31)
336
(31)
379
(33)
426
(32)
317
(33)
359
(36)
407
(36)
295
(36)
338
(39)
384
(37)
283
(37)
325
(40)
370
(39)
260
(40)
301
(41)
345
(41)
1200 Liquid pressure
(subcool)
331
(24)
375
(25)
424
(27)
313
(28)
355
(29)
402
(31)
303
(29)
344
(32)
392
(33)
288
(32)
328
(33)
376
(36)
272
(31)
315
(35)
357
(35)
260
(34)
301
(35)
346
(36)
245
(35)
286
(37)
330
(38)
1500 Liquid pressure
(subcool)
305
(23)
348
(23)
396
(27)
290
(27)
332
(27)
380
(31)
281
(29)
323
(29)
371
(33)
270
(31)
310
(31)
358
(35)
265
(34)
306
(35)
354
(37)
256
(35)
297
(36)
345
(40)
243
(36)
283
(37)
329
(41)
- Suction pressure 120 122 122 94 97 98 83 85 86 68 70 72 53 55 57 46 47 49 37 38 39
Table 46: 3 ton heating charging chart for XA(F,H)*48F and JH(E,V)T*42F in upflow and horizontal left
Ambient
temperature
(°F)
60 47 40 30 17 10 0
CFM
Indoor
temperature
(°F)
60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80
900 Liquid pressure
(subcool)
343
(21)
385
(23)
432
(22)
322
(24)
362
(26)
407
(25)
310
(25)
350
(28)
394
(27)
293
(28)
332
(30)
376
(29)
273
(31)
313
(33)
355
(33)
262
(32)
301
(34)
342
(34)
240
(34)
277
(36)
317
(35)
1200 Liquid pressure
(subcool)
308
(20)
348
(22)
393
(23)
291
(23)
330
(24)
374
(25)
281
(24)
320
(26)
364
(27)
267
(26)
305
(28)
349
(29)
253
(29)
295
(31)
332
(32)
243
(30)
280
(32)
322
(33)
228
(32)
266
(33)
307
(34)
1500 Liquid pressure
(subcool)
284
(20)
324
(20)
368
(23)
270
(22)
308
(22)
353
(25)
262
(23)
300
(23)
345
(26)
252
(25)
289
(25)
333
(28)
240
(27)
276
(28)
320
(31)
231
(28)
268
(29)
312
(32)
218
(29)
254
(31)
296
(33)
- Suction pressure 119 121 121 94 97 98 83 85 86 68 70 72 53 55 57 46 47 49 36 37 39
Installation Manual: R-410A Outdoor Split-System Heat Pump - YH2F, THF2, RHP150 Series26
Johnson Controls Ducted Systems

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls RHP150 Series and is the answer not in the manual?

Johnson Controls RHP150 Series Specifications

General IconGeneral
BrandJohnson Controls
ModelRHP150 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals