No pulse display on the console (JAR-6000)
Possible causes:
1. Console HR cable is
broken or not in good
contact with the
connector.
2. HR receiver is out of
order
3. Chest belt is not
placed properly.
4. Console is out of
order
Fix:
1. Remove the console and check if the console HR
cable has been connected properly.
Ø Reconnect the cable.
Ø Or replace it with a new one.
2. HR receiver is damaged, replace it with a new one.
3. Place the chest belt
in the correct position.
<Remark 1>
4. Console is damaged, replace it with a new one.
<Remark 1> The correct operation of a Chest Belt.
1. Moisten the electrodes that are located on
both ends of the belt.
The belt functions will most effective when placed
close to the heart and to the skin.
2-18 Revision: 1.0 Date: 2001/06/01