7.1 Technical SPECIFICATIONS
Battery Backup Unit
Operating temperature:
-20 to +55°C
Storage temperature:
-40 to +70°C
Dimension:
184mm (W) * 205mm(D) * 38,8mm (H)
Weight Battery Backup Unit:
<1,5kg
Operating voltage:
12 - 28VDC +/-10%
Power consumption:
Charging < 70W
Charging + transmit <130W (less than 70% remaining power).
When cable between BU-872 & TR-810 is connected, the charging will be postponed when radio is
transmitting.
Battery type
Lithium-ion (SAFT)
Charge time:
Approx 4 hour at 25% remaining power
Battery capacity:
72Wh
Operating time @10W:
Approx 7,5 hour
10/30/60 duty cycle
Operating time @ 5W:
Approx 8,5 hour
Operating time @ 2.5W:
Approx 9,5 hour
84417_O&I_TR-810_E Battery Backup Unit Page 7-3