5 File Number: S-PI-0035
Table5 M7 Series Fiber Laser Cut-off Frequency Value
kHz
YDFLP-E-60-M7-M-R
Pulse Width (ns)
Cut-off frequencykHz)
Max pulse
frequency kHz
1 (CW)
-
-
2
1950
4000
4
1350
4000
6
975
4000
9
600
4000
13
412
3000
20
225
3000
30
187
3000
45
150
2000
60
135
2000
80
112
2000
100
105
1000
150
57
1000
200
45
1000
250
42
900
350
40
600
500
30
500
* The laser will have expected output power when working above the cut-off frequency. When
working below the cut-off frequency, the power will drop accordingly to maintain the output
peak power. Below chart shows the relationship between frequency and output power: