2.Installation of Scanner Unit > 2.1 Equipment Cable
2-10
2.1.5 Connection to the display-unit side terminal block
The terminal blocks of the junction box are pluggable type connectors. Connection
procedures are described below.
1) Use an attached lever or a flat-head screw driver, to press the control so
as to open the cable inlet.
2) Strip 8 to 9 mm of insulation off wire. Check the strip length and then insert
the wire until the end comes in contact.
3) Release the tool from the terminal block and tighten the cable.
4) After the cable has been connected, gently tug at the cable to ensure that
it is securely fastened.