EasyManua.ls Logo

JRC JMR-5400 Series - User Manual

JRC JMR-5400 Series
206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ISO 9001, ISO 14001 Certified
SEP. 2017 Edition 2CODE No.7ZPRD0952
PLOTTERPLOTTER
Not use the asbestos
For further information,contact:
URL Head office : http://www.jrc.co.jp/eng/
Marine Service Department
1-7-32 Tatsumi, Koto-ku, Tokyo 135-0053, Japan
           : tmsc@jrc.co.jp
           :
+81-50-3786-9201
e
-
mail
One
-
call
JMR-5400 SERIESJMR-5400 SERIES
INSTRUCTIONINSTRUCTION
MANUALMANUAL

Table of Contents

Questions and Answers

  • Z
    zsmithSep 23, 2025
    Why is trail data cleared when I turn off my JRC Marine Equipment?
    • C
      Chad EstradaSep 23, 2025
      If the power supply is turned off and the trail data is cleared without being stored on your JRC Marine Equipment, it indicates that the processing unit (NDC-1678) is faulty and requires repair from the distributor.
  • M
    Matthew AlvarezAug 27, 2025
    Why is the Gyro compass azimuth not displayed correctly on my JRC Marine Equipment?
    • V
      Victor WongAug 27, 2025
      If the azimuth of the Gyro compass is not displayed correctly on your JRC Marine Equipment, there are several potential causes: * The communication may not be set correctly, so ensure the communication settings are correct. * The power supply for the Gyro compass equipment might not be on; turn it on. * The connection with the Gyro compass equipment could be abnormal; verify the connection and, if connected to the terminal board circuit (CQD-2322), check if the corresponding LED is lit when the signal is received. If these steps don't resolve the issue, there may be a fault with the internal wiring or the processing unit (NDC-1678), requiring repair from the distributor.
  • L
    laurenlambAug 28, 2025
    What to do if the radar antenna of my JRC Marine Equipment is not getting power?
    • A
      Angela GriffinAug 28, 2025
      If the power is not supplied to the radar antenna of your JRC Marine Equipment, check the following: * Verify the connection with the radar antenna. * Check for any abnormal connections with the radar antenna that may be causing overcurrent protection to activate in the power supply unit; remove any short-circuit causes. * Inspect the 24V DC output fuse; if it's blown, replace it after addressing the cause of the blowout. The fuse is F2. If the issue persists, there may be a fault with the internal wiring, the power supply (NDB-945) inside the processing unit, or the processing unit (NDC-1678) itself, requiring repair from the distributor.
  • J
    Joseph BallardAug 29, 2025
    Why is the log not displayed correctly on my JRC Marine Equipment?
    • J
      Joshua CrossAug 29, 2025
      If log values are not displayed correctly on your JRC Marine Equipment, there are several potential causes: * The communication may not be set correctly, so ensure the communication settings are correct. * The power supply for the log equipment might not be on; turn it on. * The connection with the log equipment could be abnormal; verify the connection and, if connected to the terminal board circuit (CQD-2322), check if the corresponding LED blinks when the signal is received. If these steps don't resolve the issue, there may be a fault with the internal wiring or the processing unit (NDC-1678), requiring repair from the distributor.
  • L
    larry93Nov 22, 2025
    Why is GPS information not displayed on my JRC Marine Equipment?
    • J
      jonathanlewisNov 22, 2025
      If position information (GPS) is not displayed on your JRC Marine Equipment, there are several potential causes: * The communication may not be set correctly, so ensure the communication settings are correct. * The GPS equipment's power supply might not be on; turn it on. * The GPS equipment may not be performing positioning; check its status. * The connection with the GPS equipment could be abnormal; verify the connection and, if connected to the serial LAN interface circuit, check if the LED of the corresponding port is lit when data is received. If these steps don't resolve the issue, there may be a fault with the internal wiring, the processing unit (NDC-1678), the power supply to the serial LAN interface circuit (CMH-2370) inside junction box NQE-1143, or the serial LAN inte...
  • W
    William FoxDec 1, 2025
    Why does the radar antenna on my JRC JMR-5400 not rotate when pressing [TX/ST-BY]?
    • A
      Antonio IngramDec 1, 2025
      If the radar antenna of your JRC Marine Equipment does not rotate even if the [TX/ST-BY] button is pressed, consider the following potential causes: * The 24VDC output fuse may be blown. After removing the cause of the fuse blowout, replace the fuse. The fuse is F3. * The motor driver circuit inside of the radar antenna is not set correctly. (When NKE-1632, NKE-2632, or NKE-2632-H is connected as the radar antenna.) Set the motor driver circuit correctly. * The radar antenna rotation unit is frozen. De-freeze the frozen section by using the neck heater option. * Strong wind of relative wind velocity exceeding 100kt (about 51.5m/s) is blowing. When strong wind of relative wind velocity exceeding 100kt is blowing, the radar antenna does not rotate due to the protection function. If...
  • L
    Laura MendezSep 13, 2025
    What to do if the display is frozen on my JRC Marine Equipment?
    • E
      Elizabeth CunninghamSep 13, 2025
      If the display is frozen on your JRC Marine Equipment, disabling the mode selection screen, it indicates that the processing unit (NDC-1678) is abnormal and requires repair from the distributor.
  • M
    Mark TurnerSep 14, 2025
    Why can't radar images be superimposed on my JRC Marine Equipment?
    • B
      Brittney LucasSep 14, 2025
      If radar images cannot be superimposed on your JRC Marine Equipment, there are several potential causes: * The connection with the radar antenna is abnormal; check the connection. * The connection with the radar indicator is abnormal; check the connection. If these steps don't resolve the issue, the internal wiring or the processing unit (NDC-1678) may be faulty, requiring repair from the distributor.
  • J
    Jill HarrisSep 7, 2025
    What to do if the monitor of my JRC JMR-5400 has no power?
    • C
      chapmandeborahSep 8, 2025
      If the power is not supplied to the monitor of your JRC Marine Equipment, it may be because the display unit is not activated. Activate the display unit. If the issue persists, the internal wiring or the display (NWZ-208/NWZ-214) may be faulty, requiring repair from the distributor.
  • J
    joanadkinsSep 5, 2025
    What does it mean when my JRC JMR-5400 Marine Equipment displays 'System has detected an error'?
    • N
      Nicholas DennisSep 5, 2025
      If the following popup window is displayed on your JRC Marine Equipment: "System has detected an error. Turn the power off and on again," it indicates that a communication error has occurred. Close the popup window, and after confirming it is safe to do so, turn the power off and then on again.

Summary

Preface

Safety Cautions

Cautions for High Voltage

Warnings about high voltage hazards and precautions for safe operation.

Precautions for Rescue of Victim of Electric Shock

Steps to follow when a victim of electric shock is found, including first aid.

Emergency Measures

Method of First-Aid Treatment

Detailed steps for administering first-aid treatment to an injured person.

Cardiopulmonary Resuscitation (CPR) Flow

Specific CPR Procedures

Detailed steps for performing CPR, including scene safety and victim assessment.

Pictorial Indication

Meanings of Pictorial Indication

Definitions and explanations of DANGER, WARNING, and CAUTION indications.

Precautions upon Equipment Operation

DANGER Warnings

Critical warnings for equipment operation, emphasizing hazards like fire or electric shock.

WARNING Warnings

Warnings about potential equipment failure, electric shock, or accidents due to improper operation.

Notations

Operation Notations

Explains notations for trackball operations like click and double-click.

Section 2: Basic Operations and Mode Screen

Changing the Mode

Instructions on switching between radar, synthesis, and plotter modes.

Mode Screen Sections and Features

Overview of the different sections and elements on the mode screen.

Section 3: Operations on the Chart Screen

Displaying Chart in Multi-View

How to divide the chart screen into multiple views.

Operating Multi-View Screen

Behavior and functions within the multi-view screen, including area selection.

Section 4: Route Planning

Overview of Destination Route

Basic concept of creating destination routes with optional plotter.

Creating New Destination Route

Steps to create a new destination route by registering proposed destinations.

Section 5: Route Monitoring

Starting Route Monitoring

How to start route monitoring by loading or specifying a route.

Route Monitoring Settings

Configuring route monitoring settings via View or Settings menus.

Section 6: Settings

Chart Settings

Settings related to chart operations, including registering ports and displaying charts.

Screen Display Settings

Settings for configuring the display of the own ship symbol.

Section 7: Specifications

Plotter Functions Specifications

Technical specifications for plotter functions like projection, scale, and colours.

Appendix A: Alert List

Alarms List

List of alarm messages and their explanations, requiring immediate attention.

Warnings List

List of warning messages and their explanations, indicating potential future issues.

Appendix B: Menu List and Materials

Menu List

Shows menus and dialogue items organized by target menu.

Menu: Route Planning (Destination Route)

Menu structure for planning destination routes.

JRC JMR-5400 Series Specifications

General IconGeneral
BrandJRC
ModelJMR-5400 Series
CategoryMarine Equipment
LanguageEnglish

Related product manuals