Section 3 Operations on the Chart Screen  3-4 
 
[CCRP EBL/VRM] menu 
This context menu is used to operate EBL/VRM using the ship position as the measurement base 
point. 
The following menu items are available. 
•  Make EBL1/VRM1 
•  Make EBL2/VRM2 
•  Make EBL1 
•  Make EBL2 
•  Make VRM1 
•  Make VRM2 
 
3.2.1  Operation via [Dropped EBL/VRM] -   
[Make EBL1/VRM1] or [Make EBL2/VRM2] 
Operations are common in EBL1/VRM1 and EBL2/VRM2. The following description is based on 
EBL1/VRM1. 
1  Right-click on the chart to display the context menu. 
2  Select [Dropped EBL/VRM] - [Make EBL1/VRM1] from the context menu. 
EBL1 is displayed and the measurement base point is displayed on the cursor. 
3  Move the cursor to any position and click. 
The measurement base point will be fixed. 
4  Move the cursor to adjust the direction and distance and click at any position. 
The ELB1 direction and VRM1 distance will be fixed. 
 
3.2.2  Operation via [Dropped EBL/VRM] -   
[Make EBL1] or [Make EBL2] 
Operations are common in EBL1 and EBL2. The following description is based on EBL1. 
1  Right-click on the chart to display the context menu. 
2  Select [Dropped EBL/VRM] - [Make EBL1] from the context menu. 
EBL1 is displayed and the measurement base point is displayed on the cursor. 
3  Move the cursor to any position and click. 
The measurement base point will be fixed. 
4  Move the cursor to adjust the direction and click at any position. 
The ELB1 direction will be fixed.