2.4 PRECAUTIONS
Microwave radiation level:
Keep away from a scanner when it is transmitting.
The high level of microwave is radiated from the front face of the
scanner specified below. The microwave exposure at close
range could result in injuries (especially of the eyes).
Microwave radiation level
System 50 W/m
2
10 W/m
2
2.5 W/m
2
NKE-2103 n/a 26cm 123cm
NKE-1125/1129/2254 5cm 81cm 162cm
NKE-1130/1139 11cm 76cm 181cm
NKE-2632 1.38cm 3.1cm 209.76cm
NKE-1632 1.45cm 3.25cm 128.37cm
Make sure to install the scanner at a place higher than human
height.
Direct exposure to electromagnetic waves at close range will
have adverse effects on the human body.
Direct exposure to electromagnetic waves at close range will
have adverse effects on the human body. When it is necessary to
get close to the scanner for maintenance or inspection
purposes, make sure to turn the indicator power switch to "OFF"
or "STBY."
Direct exposure to electromagnetic waves at close range will
have adverse effects on the human body.
When conducting maintenance work, make sure to turn off the
power so that the power supply to the equipment is completely
cut off.
Some equipment components can carry electrical current even
after the power switch is turned off, and conducting maintenance
work without unplugging the power connector may result in
electrocution, equipment failure, or accidents.