7. SPECIFICATIONS
JCY-1900
/
1950
V
DR Service Manual
82
DOC No. 7ZPNA4409
7.2. NDH-339 Float Free Capsule Unit
Performance
a) Interface
1) Standard IEEE802.3 (10Base-T/ 100Base-TX)
2) Protocol TCP/IP
b) Recording duration and capacity
1) Duration 48 hours
2) Capacity 64GB
c) Data Recording Interval
1) Sensor data depends on the input from the sensors (usually 1 second)
2) Audio data continuous (1 audio file / minute)
3) Image data 15 seconds per each image
(X-Band Radar, S-Band Radar, Main-ECDIS and Sub-ECDIS)
d) Locator Light Flashing LED
e) Transmitter operation
1) Operating time 168 hours
2) Expectant battery age 4 or 5 years after Installing
(follow the Classification Society)
3) Battery specifications Lithium battery
DC +7.2V 18Ah
f) 406MHz Transmitter
1) Frequency 406.037MHz
2) Output power 5W ± 2dB
g) 121.5MHz Transmitter
1) Frequency 121.5MHz
2) Output power Under 100mW
h) Hydrostatic Release Mechanism
1) Operating depth 2 to 4m
2) Expectant age 2 years
i) Compass safety distance
1) Standard 0.8m
2) Steering 0.8m
Environmental condition
a) Degree of protection 10m depth at 5minutes
b) Operating temperature -20 °C to +55 °C (IEC61097-2 satellite EPIRB)
c) Storage temperature -30 °C to +70 °C (IEC61097-2 satellite EPIRB)
General specification
a) Input voltage range Power Over Ethernet (IEEE802.3af)
b) Power consumption 15W
c) Size 235.8(w) x 214.2(d) x 528.5(h) mm
d) Mass 5.2kg (including the EPIRB, bracket and cable).
e) Color ORANGE.