EasyManua.ls Logo

JRC JCY-1900 - Digital Signal Converter 64 CH

JRC JCY-1900
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. SPECIFICATIONS
JCY-1900
/
1950
V
DR Service Manual
89
DOC No. 7ZPNA4409
7.7. NCT-83 Digital Signal Converter 64CH
Performance
a) Dry contact input Dry contact
b) Dry contact input channel Up to 64 channels
c) Contact closure interface
1) Driving power supply DC +12V
2) logic Normal Close / Normal open
d) Communication port Connect to the RCU
e) Output sentence IEC61162-1
f) Compass safety distance
1) Standard 0.4m
2) Steering 0.2m
Analog Interface (option)
If the optional analog to digital conversion board CEF-60 is added.
a) Analog signal Input channel Up to 8 channels
b) Analog signal interface
1) Voltage range ±1V, ±5V, ±10V
2) Current range ±20mA
c) Communication port Connect to the RCU.
(Same port as dry contact signals)
d) Output sentence IEC61162-1
XDR sentence – Transducer measurement
Environmental condition
a) Operating temperature -15 °C to +55 °C (IEC 60945 protected type)
b) Temperature and humidity +40 °C, 93% (non condensing)
c) Vibration 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Protection class IP22
General specification
a) Power voltage AC 100 to 120V ± 10%, 1-phase 50/60Hz (IEC 60945)
AC 200 to 240V ± 10%, 1-phase 50/60Hz (IEC 60945)
b) Power consumption 25VA
c) Size 300(w) x 130(d) x 420(h) mm
d) Mass 4.2kg
e) Color N7 semi-gloss