2. MAINTENANCE
JCY-1900
1950
DR Service Manual
26
DOC No. 7ZPNA4409
2. MAINTENANCE
2.1. Replacement Parts list
The following is replacement parts. Using the OPU, check the expiration date. (Refer to 3.4.3.)
* When replacing parts, it is necessary to set the expiration date with maintenance software. (Refer to 2.9.2)
No Name of Component
Parts name
(Type Name)
Expiration date Replacement method
1
RCU(NDV-1900/1950)
Replacement Parts
Kit (7ZZNA4134)
FAN 2 pieces
(7BFNA4002)
4.5 years after installing Refer to 2.5.3.
Battery
(CBN80)
4.5 years after manufac-
turing
Refer to 2.5.1.
2
FPC(NDH-338)
Beacon
(7ZZNA4138)
3 years after manufactur-
ing
Refer to 2.4.1.
3
FFC(NDH-339)
Battery
(TBD)
4 or 5 years after
Installing
(follow the Classification
Society)
(*1)
HRU (Hydrostatic
Release Unit)
(TBD)
2 years after installing
(*1)
4
OPU(NCG-1900/1950)
LCD
Operating time 50,000
hours
Replace the unit.
5
FGU(NWP-69)
Fan
(7BFNA4001)
4.5 years after installing Refer to 2.7.1.
*1 It is necessary to receive the capsule manufacturers (JOTRON) training for Replacement of FFC.