7. SPECIFICATIONS
JCY-1900
1950
DR Service Manual
90
DOC No. 7ZPNA4409
7.8. NCT-82 Digital Signal Converter 32CH
Performance
a) Dry contact input Dry contact
b) Dry contact input channel Up to 32 channels
c) Contact closure interface
1) Driving power supply DC +12V
2) logic Normal Close / Normal open
d) Communication port Connect to the RCU
e) Output sentence IEC61162-1
f) Compass safety distance
1) Standard 0.3m
2) Steering 0.2m
Analog interface (option)
If the optional analog to digital conversion board CEF-60 is added.
a) Analog signal Input channel Up to 8 channels
b) Analog signal interface
1) Voltage range ±1V, ±5V, ±10V
2) Current range ±20mA
c) Communication port Connect to the RCU.
(Same port as dry contact signals)
d) Output sentence IEC61162-1
XDR sentence – Transducer measurement
Environmental condition
a) Operating temperature -15 °C to +55 °C (IEC 60945 protected type)
b) Temperature and humidity +40 °C, 93% (non condensing)
c) Vibration 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Protection class IP22
General specification
a) Power voltage AC 100 to 120V ± 10%, 1-phase 50/60Hz (IEC 60945)
AC 200 to 240V ± 10%, 1-phase 50/60Hz (IEC 60945)
b) Power consumption 20VA
c) Size 300(w) x 130(d) x 230(h) mm
d) Mass 2.8kg
e) Color N7 semi-gloss