EasyManua.ls Logo

JRC JCY-1900 - Data Acquisition Unit

JRC JCY-1900
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. SPECIFICATIONS
JCY-1900
/
1950
V
DR Service Manual
92
DOC No. 7ZPNA4409
7.10. NCT-84 Data Acquisition Unit
Performance
a) Input sensor channel
1) IEC61162-1 8 channels
2) IEC61162-2 2 channels
b) Interface to the RCU
1) Standard IEEE802.3 (10Base-T/ 100Base-TX)
2) Protocol TCP/IP
c) Compass safety distance
1) Standard 0.9m
2 Steering 0.5m
Gyro interface
a) Signal input Synchronized signal for the gyro compass
Ratio: 360X, 180X, 90X, 36X
Voltage: AC24 to 115V
Frequency: 50/60/400Hz
Step signal for the gyro compass
Ratio: 360X, 180X, 90X, 36X
Voltage: DC21.6 to 70V
Pulse signal for the speed log
Ratio: 800P / 400P / 200P / 100P
Voltage: DC0 to 50V (threshold 2V)
b) Output sentence IEC61162-1
THS sentence - True heading and status VBW sentence - Dual
ground/water speed
Environmental condition
a) Operating temperature -15 °C to +55 °C (IEC 60945 protected type)
b) Temperature and humidity +40 °C, 93% (non condensing)
c) Vibration 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Protection class IP22
General specification
a) Power voltage AC 100 to 120V ±10%, 1-phase 50/60Hz (IEC 60945)
AC 200 to 240V ±10%, 1-phase 50/60Hz (IEC 60945)
b) Power consumption 18VA.
c) Size 300(w) x 130(d) x 420(h) mm
d) Mass 4.3kg
e) Color N7 semi-gloss

Table of Contents

Other manuals for JRC JCY-1900