7. SPECIFICATIONS
JCY-1900
/
1950
V
DR Service Manual
85
DOC No. 7ZPNA4409
Environmental condition
a) Operating temperature -15 °C to +55 °C (IEC 60945 protected type)
b) Temperature and humidity +40 °C, 93% (non condensing)
c) Vibration 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
d) Protection class IP22
General specification
a) Power voltage AC100 - 120V ±10%, 1-phase 50/60Hz (IEC 60945)
AC 200 - 240V ±10%, 1-phase 50/60Hz (IEC 60945)
b) Power consumption
(including the fixed protective capsule unit,
and the float-free capsule unit, the operation
panel unit, and microphone)
230W (in UPS battery charge)
70W (in normal operation)
c) Size 419.5(w) x 214.0(d) x 480.5(h) mm
d) Mass 22.5kg
e) Color N7 semi-gloss texture