1. OUTLINE
JCY-1900
1950
DR Service Manual
9
DOC No. 7ZPNA4409
Item JCY-1900/1950 JCY-1800/1850
Taking recorded data Download software is attached.
・Can select the recorded data to be
downloaded from the internal
storage by specifying the time
span.
・Recorded data of 12 hours worth
can be taken within 2.5 hours.
Same as JCY-1900
Playback Playback software is attached. Same as JCY-1900
* The under lined parts in JCY-1900 column meet the demands of the new specifications.
2) Option specifications
Item JCY-1900/1950 JCY-1800/1850
RGB input of the
image recording
signal
Input is possible with the optional
Frame Grabber Unit (FGU).
Number of RGB inputs: 2ch
Connectable maximum number of
FGU: 3 units
* 2ch/unit x 3 units
Standard
Dry contact signal
input
Input is possible with the optional
Digital Signal Convertor (DSC).
Number of input dry contacts:
NCT-82: 32ch
NCT-83: 64ch
Same as JCY-1900
Number of input dry contacts:
NCT-63: 16ch
NCT-72: 64ch
Analog signal input Input is possible with the optional
A/D Convert Board (ADC).
Number of channels: 8ch
* Can mount on Digital Signal Con-
vertor (DSC).
Same as JCY-1900
Sensor input ex-
pansion
Expandable with the Data Acquisi-
tion Unit (DAU).
IEC61162-2: 2ch
IEC61162-1: 8ch
None
Gyro input Input is possible with the Gyro I/F
Board (GIF).
Input is possible with the Recording
Control Unit (RCU).