4. TROUBLE SHOOTING
JCY-1900
/
1950
V
DR Service Manual
69
DOC No. 7ZPNA4409
Error
codes
Error
type
Indication Contents Actions to take
062 INFO RCU fan expiration
date
The expiration date is less than
one year.
1) Check the expiration date that is set on maintenance software.
Refer to Service manual 2.9.2.
2) Replace the Fan. Refer to Service manual. 2.5.3
063
-065
INFO FGU1(~3) fan
expiration date
The expiration date is less than
one year.
1) Check the expiration date that is set on maintenance software.
Refer to Service manual. 2.9.2
2) Replace the Fan. Refer to Service manual 2.7.1.
066 INFO Float-free capsule
HRU expiration date
The expiration date is less than
one year.
1) Check the expiration date that is set on maintenance software.
Refer to Service manual. 2.9.2
2) Replace the HRU. Refer to Service manual 2.1.
101 CAUTION Fixed capsule short
store period
The FPC's data recording possi-
ble time has decreased.
1) In order to down radar image file size, adjust gain of radar echo.
2) If not improved within 48 hours, replace the FPC.
* This alert occurs when radar picture size increases temporarily by an echo
etc. Within 48 hours, the past recording is deleted, and an alert is restored.
102 WARNING Fixed capsule
connection failure
The RCU cannot communicate
with the FPC.
1) Check the connection(Refer to Installation Manual (Hardware Part) 3.3.2),
Reboot the RCU.
2) Replace the FPC.
103 CAUTION Fixed capsule
recording failure
The FPC cannot record data. 1) Reboot the RCU
2) Replace the FPC.