7 – 35
7.5
7.5.3.9   Setting PRF
This function is used to change the repetition frequency to reduce mutual interference.
Procedures
1. Press the 
SUB
MENU
 key to open the SUB MENU.
2. Press the 
9
 key twice to open the INIT SETTING #2 menu.
3. Press the 
4
 key twice to select "SETTING OF PRF".
4. Press the 
RANGE
 or 
RANGE
 or 
BRILL
 key to select number. (0-39)
5. Press the 
ENT
 key to confirm the setting.
Exit
6. Press the 
SUB
MENU
 key.
Init setting #2
INIT SETTING #2
Press an item number key.
0. PREVIOUS MENU
1. BEARING ADJUSTMENT
2. RANGE ADJUSTMENT
3. TUNE ADJUSTMENT
4. SETTING OF PRF 0
5. PM ADJUSTMENT
6.
7. DIAGNOSTIC MENU
8. MAINTENANCE MENU
9. NEXT MENU
To close this menu, Press (SUB MENU) key.
Note
● By pushing the [BRILL] control the pulse repetition frequency is directly changed without opening the
SUB MENU.