7 – 49
7.5
7.5.6.2   Antenna Switch
"DISCARD" is set on regular shipment.
Transmission can be enabled while the rotation of the scanner unit is stopped.
Procedures
1. Follow procedures 1 to 3 in subsection 7.5.6.1 to open the MAINTENANCE
MENU.
2. Press the 
3
 key to select "ANTENNA SWITCH".
3. Press the 
3
 key to select "TRANSFER" or "DISCARD".
When "TRANSFER" is selected, transmission is enabled while the rotation of the
scanner unit is stopped.
4. Press the 
ENT
 key to confirm the setting.
Exit
5. Press the 
SUB
MENU
 key.
7.5.6.3   Partial Master Reset
This function is used to set the same settings as on shipment.  Since the contents set by the user are cleared,
only our service personnel is allowed to use this function.
Procedures
1. Follow procedures 1 to 3 in subsection 7.5.6.1 to open the MAINTENANCE
MENU.
2. Press the 
4
 key to select "PARTIAL MASTER RESET".
3. Press the 
4
 key to set the system in the partial master reset standby
mode.
4. Press the 
ENT
 key to reset or the 
CLR
 key not to reset according to
the direction on the screen.
After resetting, the screen which appears after turning the power on is displayed.
Exit
5. Press the 
SUB
MENU
 key.
7.5.6.4   Total Master Reset
This function is used by our service personnel after the software is written.  Users are
requested never to use this function.