3.5    GENERAL OPERATIONS 
3ņ42 
3 
y
y y
Changing the interval (distance from own ship) and length of parallel index lines 
 
 
  Procedure    1  Press the [VRM] control. 
 
Ɣ  Turn the mode on using the jog dial. 
  Press the jog dial to turn the mode on. 
 
Ɣ  Turn the mode on from the menu screen. 
  Turn the mode on by following the steps 
below: 
 Press the [Radar Menu] key. 
          3    Marker Setting 
          5    Parallel Line 
 Press the [1] key to set the Operation Mode to 
Parallel Index Line mode. 
 
(*)  These steps are not required if the mode is 
already on. 
 
2  Press the [EBL] while the Parallel Index 
Line mode is on. 
 
Press the jog dial to scroll target parallel index lines. 
A parallel index line currently in use is shown as follows: 
    EBL Control 
    PI 1 Bearing 
 
3  Press the [EBL] control. 
 
Press the jog dial to change the VRM target in the following order: 
    Interval setting  Ѝ  end point 1 setting  Ѝ  end point 2 setting  Ѝ  interval setting   
Length of the index line changes as the position of end point 1 or end point 2 changes. 
 
When the jog dial is turned... 
Interval of index lines, distance to end point 1, and distance to end point 2 are changed.