[II] Reception Monitor Adjustment (MON Indicator Adjustment) 
 
Adjust the circuit for monitoring the reception performance of the radar equipment. 
 
 
  Procedure    1  Hold down [RADAR MENU] key. 
 
The Code Input Menu will appear. 
 
2  Press [0] key. 
 
3  Move the cursor onto the “ENT” button 
in the Code Input menu, and press 
[ENT] key. 
 
The Adjust Menu will appear. 
 
4  Open Adjust Menu. 
 
4    TXRX Setting 
4    MON 
2    MON Indicator Adjustment 
 
5  Increase or decrease the adjustment 
value so that the performance monitor level indicator will be adjusted to 
"8." 
 
 
 
6  Press the    EXIT    button to close the adjustment menu. 
 
 
Note:  During performance monitor adjustment, all acquisitions by the target tracking function are released. 
  The released target acquisitions are not recovered.