7.5    MAINTENANCE MENU 
ņ58 
7 
yyy
yyyy
[II] Motor Run Time Clear (Motor Time Clear) 
 
Clear the transmission time of the antenna unit. 
Perform the following procedure to clear the transmission time when the magnetron is replaced. 
 
Note:  This function can be performed only when the scanner is connected to NKE-2043, NKE-2063A,   
  NKE-2103, and NKE-2254. 
 
  Procedure    1  Hold down [RADAR MENU] key. 
 
The Code Input Menu will appear. 
 
2  Press [0] key. 
 
3  Move the cursor onto the “ENT” button 
in the Code Input menu, and press 
[ENT] key. 
 
The Adjust Menu will appear. 
 
4  Press [2] key. 
 
The Maintenance Menu will appear. 
 
5  Press [6] key. 
 
Press [3] key. 
 
6.  Select    Yes    in the Motor Run Time Clear Confirmation Window. 
 